beautypg.com

Depth filter specifications – Culligan HD-726 User Manual

Page 3

background image

H

I

-F

LO

®

D

EPTH

F

ILTERS

FOR

S

EDIMENT

R

EDUCTION

S

PECIFICATIONS

AND

O

PERATING

D

ATA

Hi-Flo 55

Hi-Flo 50

MODEL NUMBER

HD-202 HD-242 HD-302 HD-362 HD-423 HD-483 HD-544 HD-604 HD-726 HD-846

Peak

Service Flow @

gpm

30

45

75

100

150

190

240

300

440

600

Pressure Drop

@ psi

@ 3

@ 4

@ 7

@ 10

@ 6

@ 10

@ 8

@ 10

@ 10

@ 10

L/min

114

170

284

379

568

719

908

1,140

1,670

2,270

@ kPa

@ 21

@ 28

@ 42

@ 69

@ 41

@ 69

@ 55

@ 69

@ 69

@ 69

Normal

Service Flow @

gpm

15

20

35

50

70

90

110

140

200

270

Pressure Drop

@ psi

@ 1

@ 1

@ 2

@ 3

@ 2

@ 3

@ 3

@ 2

@ 2

@ 2

L/min

57

76

132

189

265

340

420

530

750

1,020

@ kPa

@ 6.9

@ 6.9

@ 14

@ 21

@ 14

@ 20

@ 20

@ 14

@ 14

@ 14

Backwash Flow

gpm

30

45

70

100

135

188

210

270

400

540

L/min

114

170

265

379

511

712

795

1,020

1,510

2,040

Tank Size

Diameter

in

20

24

30

36

42

48

54

60

72

84

mm

510

610

760

910

1,070

1,220

1,370

1,520

1,830

2,130

Sideshell

in

48

48

48

54

54

60

60

60

60

60

mm

1,220

1,220

1,220

1,370

1,370

1,520

1,520

1,520

1,520

1,520

Pipe Size

Inlet/Outlet

in

2

2

2

2

3

3

4

4

6

6

Media Volume

ft

3

5

8

12

17

23

32

40

49

70

97

m

3

0.142

0.227

0.340

0.481

0.651

0.906

1.13

1.39

1.98

2.75

Ship Weight, Approx.

lb

870

1,150

1,750

2,530

3,550

7,000

8,800

10,800 18,500 25,000

kg

390

520

790

1,150

1,610

3,175

4,000

4,900

8,390 11,340

NOTES:
1 Service flow rates are based on 7 gpm/ft

2

(26 L/m

2

/min) for Normal and 15 gpm/ft

2

(57 L/m

2

/min) for Peak Flow rates. Actual service rate can vary from

2 to 20 gpm/ft

2

(8 - 76 L/m

2

/min) depending upon the application and the raw water.

2 Backwash flow rates are based on 12-14 gpm/ft

2

(45-53 L/m

2

/min) using 50° F (10° C) water. A different backwash rate may be required depending upon

water temperature or the type of carbon used.

3 Operational, maintenance and replacement requirements are essential for this product to perform as advertised. Service is available through independently

operated Culligan dealerships.

Commercial Systems

©2000 Culligan

1-800-CULLIGAN

www.culligan.com

Printed in USA Rev. 4/00

DCO 992587

SL-0070

Moore Part No. 46924

This manual is related to the following products: