beautypg.com

Carbon filter specifications – Culligan HD-726 User Manual

Page 4

background image

H

I

-F

LO

®

C

ULLAR

®

A

UTOMATIC

F

ILTERS

FOR

D

ECHLORINATION

AND

O

RGANIC

A

DSORPTION

S

PECIFICATIONS

AND

O

PERATING

D

ATA

Hi-Flo 55 Hi-Flo 50

MODEL NUMBER HR-202 HR-242 HR-302 HR-362

HR-423

HR-4825 HR-543 HR-603 HR-724 HR-844

Dechlorination

Service Flow @

gpm

20

30

50

70

100

125

160

200

280

380

Pressure Drop

@ psi

@ 2

@ 2

@ 4

@ 8

@ 13

@ 16

@ 18

@ 13

@ 12

@ 16

L/min

76

114

189

265

379

473

606

757

1,060

1,440

@ kPa

@ 14

@ 14

@ 28

@ 55

@ 90

@ 110 @ 124

@ 90

@ 83

@ 110

Organics Adsorption

Service Flow @

gpm

10

15

25

35

50

65

80

100

140

200

Pressure Drop

@ psi

@ 1

@ 1

@ 2

@ 3

@ 4

@ 4

@ 6

@ 4

@ 5

@ 6

L/min

38

57

95

132

189

246

303

379

530

757

@ kPa

@ 6.9

@ 6.9

@ 14

@ 21

@ 28

@ 28

@ 41

@ 28

@ 34

@ 41

Backwash Flow

gpm

20

30

45

70

100

136

160

210

270

400

L/min

76

114

170

265

379

515

606

795

1,020

1,510

Tank Size

Diameter

in

20

24

30

36

42

48

54

60

72

84

mm

510

610

760

910

1,070

1,220

1,370

1,520

1,830

2,130

Sideshell

in

48

48

48

54

54

60

60

60

60

60

mm

1,220

1,220

1,220

1,370

1,370

1,520

1,520

1,520

1,520

1,520

Pipe Size

Inlet/Outlet

in

2

2

2

2

2

2.5

3

3

4

4

Media Volume

ft

3

6

8

12

18

24

32

40

48

70

96

m

3

0.170

0.227

0.340

0.510

0.680

0.910

1.13

1.36

1.98

2.72

Ship Weight, Approx.

lb

530

670

1,000

1,420

2,000

5,200

6,500

8,000

12,500 17,000

kg

240

300

450

640

910

2,400

2,900

3,600

5,700

7,700

NOTES:
1 Service flow rates are based on 5 gpm/ft

2

(19 L/m

2

/min) for Organic Adsorption and 10 gpm/ft

2

(38 L/m

2

/min) for Dechlorination. Actual flow rate may vary

depending upon the application and the raw water.
2 Backwash flow rates are based on 10 gpm/ft

2

(38 L/m

2

/min) using 50° F (10° C) water. A different backwash rate may be required depending upon

water temperature or the type of carbon used.

3 Operational, maintenance and replacement requirements are essential for this product to perform as advertised. Service is available through independently

operated Culligan dealerships.

Commercial Systems

©2000 Culligan

1-800-CULLIGAN

www.culligan.com

Printed in USA Rev. 4/00

DCO 992587