Operating

Instructions

SWT-1000

DYNALCO

SWT-1000.r2.0609

5

2.3 Outputs

2.3.1 Analog Output

SWT-1000

Type Current

0…20 / 4…20mA

Load Max.

500

ohms

Open circuit voltage

Max. 12V

Operating Mode

21

20

12

4

0

speed

[rpm]

0...20mA mode

4...20mA mode

initial value

final value

(minimal measured

value)

[mA]

Transfer functions

Normal or Inverse (rising or falling characteristic)

speed

output

normal

speed

output

invers

Resolution 12

Bit

(4096

Steps)

Max Linear error

0.1 %

Accuracy

0.5 % of the full range value.

Damping

Hardware 11 ms + Software setting (Configuration)

Temperature Drift

Typically

± 100 ppm/K, max. ± 300 ppm/K

Reaction time

Effective measuring time + 7.5ms