12


7.4 Parameter List and Ranges

If you already have a configuration file you can open and view it using the SWT-1000 Windows
Software menu
File

Æ Open

You can also connect the SWT-1000 to a PC (see section 7.2) and read back the parameters,
SWT-1000

Æ Read parameters


Once loaded into the software the parameter set may be printed via File

Æ Print

Normal Windows file handling rules apply.

7.5 Parameters

Parameters are changed in the sub menus from the drop down menu “Configuration“. Parameter
list and ranges. Factory settings are shown in bold.

Configuration < System >

Machine factor

1.0000E-07 ... 1.0000 ... 9.9999E+07

Minimum Measuring time

2 / 5 / 10 / 20 / 50/ 100 / 200 / 500 ms / 1/ 2 / 5 Seconds

Min displayed measured value

1.0000E-12 ... 1 ... 1.0000E+12

Alarm definition

Only System error System error OR Sensor Monitoring

Configuration < Sensor >

Sensor Type

Active / Passive

Sensor input

Analog (Sign) / Digital (IQ)

Sensor current minimum

0.5 ... 1.5 ... 25.0mA

Sensor current maximum

0.5 ... 25.0mA

Configuration < Analog output >

Measuring range start value

0.0000 ... 90% of the end value

Measuring range end value

1 … 2000.0 500000

Output range

0 ... 20mA / 4 ... 20mA

Time constant (Damping)

0.0 ... 9.9s

Configuration < Limits >

Status Limit

1

On / Off

Status Limit

2

On / Off

Mode Limit

1

Normal / Inverse

Mode Limit

2

Normal / Inverse

Lower Set point

Limit 1

0.1 … 200.00 … 500000

Upper Set point

Limit 1

0.1 … 300.00 … 500000

Lower Set point

Limit 2

0.1 … 400.00 … 500000

Upper Set point

Limit 2

0.1 … 500.00 … 500000

Configuration < Relay control >

Switching of control A/B

Selection of actuator

None (always control A) / Binary Input B1

Delay time

0 ... 2.000 s

Relay Assignment

Control

A

Alarm / Sensor monitor / Limit 1 / Limit 2 / Window / On /
Off

Acknowledge A

Without acknowledge (no hold function) /
Relay held when control active /
Relay held when control inactive

Acknowledge B

Alarm / Sensor monitor / Limit 1 / Limit 2 / Window / On /
Off

Acknowledge B

Without acknowledge (no hold function) /
Relay held when control active /
Relay held when control inactive