Specifications – Culligan Iron-Cleer User Manual
Page 5
Specifications
Culligan
®
Iron Cleer
®
Filters
1
Capacity based on 4 gpm and 10 mg/L of dissolved iron.
2
Measured from top of media bed to top of inlet fitting.
3
Max flow rates & pressure drop characteristics have not been validated by the Water Quality
Association.
The max specified flow rate at which the system will deliver treated water as validated by the Water
Quality Association is defined as service flow.
1
10” Iron Cleer
12” Iron Cleer
Control Valve
1” 5-cycle reinforced
thermoplastic
1” 5-cycle reinforced
thermoplastic
Timer
Electro-mechanical
Electro-mechanical
Overall Conditioner Height
67”
65”
Media Tank Dimensions (D
x H)
2 ea. 10” x 54” tanks
2 ea. 12” x 52” tanks
Filter Media Type
1.0 cu. ft. birm
1.5 cu. ft. birm
Underbedding
G-50
35 lbs.
35 lbs.
Cullsan U
25 lbs.
25 lbs.
Capacity
1
1400 gallons
2000 gallons
Freeboard
2
21”
18”
Max. Clear Water (Soluble)
Iron
10 ppm
10 ppm
Max. Hydrogen Sulfide
5.0 ppm
5.0 ppm
Minimum Alkalinity
100 ppm
100 ppm
pH
7.0 - 8.5
7.0 - 8.5
Service Flow @ Pressure Drop (Clean Bed)
Normal
5 gpm @ 9 psi
7 gpm @ 10 psi
Maximum
3
6 gpm @ 9 psi
9 gpm @ 14 psi
Operating Pressure
20-60 psi
20-60 psi
Operating Temperature
33-120° F (1-48° C)
33-120° F (1-48° C)
Electrical Requirements
120 Volts/60 Hz
120 Volts/60 Hz
Power Consumption,
Continuous/Maximum
3 watts/203 watts
3 watts/203 watts
Drain Flow, Maximum
10 gpm (5.5 gpm min. required) 10 gpm (8.0 gpm min. required)
Regeneration Time
Backwash
5 - 20 minutes
5 - 20 minutes
Fast Rinse
5 - 20 minutes
5 - 20 minutes