Programming, Time of day, Time of regeneration – Culligan Iron-Cleer User Manual
Page 10: Backwash time
Programming
6
Make sure either inlet water supply is turned off, then supply power to the timer. The display will power
up flashing “12:00 PM” and the motor will energize and cycle the control, without stopping, the home
position. This is required to ensure that the control is in the home position.
The timer uses four buttons:
Button
Description
Set-up / Enter Key
(Status)
Advance timer through
display options
Regeneration Key
(REGEN)
Initiate a regeneration
Toggle Down Key (“-”)
Decrease the setting
Toggle Up Key (“+”)
Increase the setting
Time of Day
This setting is used to program the current time of day.
When in this step the display will first show “tod” for two
seconds.
After “tod” is displayed, “12:00 PM” will display (or the
current set time if already programmed) and the minutes
will flash.
• The minutes are adjusted with the “+” or “-”
key until the correct value is displayed.
• Press the “Regen” key to flash the hours.
Adjust with the “+” or “-” key until the correct
time is displayed.
Pressing the “Status” key will move to the next
programming step. Pressing “Regen” will move back to
the minutes adjust.
Time of Regeneration
This setting is used to program the time at which
a regeneration is to occur in the delay mode, or in
immediate mode with time clock backup on. The display
will first show “tor” for two seconds.
After “tor” is shown the display will then show the
default of 2:00 AM (or the current programmed time of
regeneration if already set). The time can be adjusted in
30 minute increments by pressing the “+” or “-” keys.
Pressing the “Status” key will save the setting and move
to the next programming step.
Backwash Time
This setting is used to program the cycle 1 time that
is usually backwash. The time of the cycle is kept in
minutes. The display will show “buu” in the display for
two seconds and then the cycle time in the right most
digits. Adjust the value with the “+” or “-” keys.