Performance
Data Sheet
Culligan
®
10” and 12” Iron-Cleer
®
Water Filters
Important Notice — Read this data sheet and compare the capabilities of the unit to your actual
water treatment needs. Culligan recommends that you have your water supply tested to determine
these needs before purchasing a water treatment unit.
Culligan knows the more informed you are about your water treatment system, the more confident
you will be about its performance. It’s because of this more than sixty five years of commitment to
our customers that Culligan is providing this Performance Data Sheet to its customers.
Manufacturer
Culligan International Company
9399 West Higgins Road, Suite 1100, Rosemont, IL 60018
(847) 430-2800
www.culligan.com
Substance Reduction
Model
Substance USEPA SDWA*
MCL (MG/L)
Percent
Reduction
Average Influent
Concentration
Level
Average Effluent
Concentration
Level
10” Iron-Cleer
Iron
0.3 mg/L
99
9.82 mg/L
< 0.1
12” Iron-Cleer
Iron
0.3 mg/L
99
9.82 mg/L
< 0.1
*
United States Environmental Protection Agency Safe Drinking Water Act
Testing Conditions
Capacity: 1,400 gallons (10” Iron-Cleer)
2,000 gallons (12” Iron-Cleer)
Temperature:
63°F - 73°F
Flow Rate:
5 gpm (10” Iron-Cleer)
7 gpm (12” Iron-Cleer)
pH:
8.0
Pressure:
60 psi
Acidity: Non-Corrosive
Rated Pressure Drop @ 5 gpm: 9 psi (10” Iron-Cleer)
Rated Pressure Drop @ 7 gpm: 10 psi (12” Iron-Cleer)
Operating Conditions
Water Pressure Limits:
20 - 60 psi
Temperature Limits: 33 - 120°F
Electrical Characteristics:
120V/60 Hz 3 Watts continuous
The 10” and 12” Iron-Cleer filters have been tested and certified by WQA against S-200 for the
effective reduction of iron.
The 10” and 12” Iron-Cleer filters have been tested by WQA against NSF/ANSI 42 for the reduction of iron. The concentration of
iron in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the
system as specified in NSF/ANSI 42.
Testing was performed under laboratory conditions, actual results may vary.
Performance Indicator: If water flow decreases or a noticeable odor returns, the filter should be reconditioned. If conditions do not
improve, contact your local Culligan Man. He can determine if your filter requires servicing.
Regeneration Frequency: Regeneration frequency will vary depending upon water conditions.
Refer to your Installation and Operation Instructions, Parts List and Printed Warrantees for more specific product information.
To avoid contamination from improper handling and installation, your system should only be installed and serviced by your
Culligan Man. Performance may vary based on local water conditions. The substances reduced by this product are not
necessarily in your water.
Buyer Signature
Date
Seller Signature
Date