beautypg.com

Performance data sheet – Culligan Iron-Cleer User Manual

Page 20

background image

Performance

Data Sheet

Culligan

®

10” and 12” Iron-Cleer

®

Water Filters

Important Notice — Read this data sheet and compare the capabilities of the unit to your actual

water treatment needs. Culligan recommends that you have your water supply tested to determine

these needs before purchasing a water treatment unit.
Culligan knows the more informed you are about your water treatment system, the more confident

you will be about its performance. It’s because of this more than sixty five years of commitment to

our customers that Culligan is providing this Performance Data Sheet to its customers.

Manufacturer

Culligan International Company

9399 West Higgins Road, Suite 1100, Rosemont, IL 60018

(847) 430-2800

www.culligan.com

Substance Reduction

Model

Substance USEPA SDWA*

MCL (MG/L)

Percent

Reduction

Average Influent

Concentration

Level

Average Effluent

Concentration

Level

10” Iron-Cleer

Iron

0.3 mg/L

99

9.82 mg/L

< 0.1

12” Iron-Cleer

Iron

0.3 mg/L

99

9.82 mg/L

< 0.1

*

United States Environmental Protection Agency Safe Drinking Water Act

Testing Conditions

Capacity: 1,400 gallons (10” Iron-Cleer)

2,000 gallons (12” Iron-Cleer)

Temperature:

63°F - 73°F

Flow Rate:

5 gpm (10” Iron-Cleer)

7 gpm (12” Iron-Cleer)

pH:

8.0

Pressure:

60 psi

Acidity: Non-Corrosive
Rated Pressure Drop @ 5 gpm: 9 psi (10” Iron-Cleer)
Rated Pressure Drop @ 7 gpm: 10 psi (12” Iron-Cleer)

Operating Conditions

Water Pressure Limits:

20 - 60 psi

Temperature Limits: 33 - 120°F
Electrical Characteristics:

120V/60 Hz 3 Watts continuous

The 10” and 12” Iron-Cleer filters have been tested and certified by WQA against S-200 for the

effective reduction of iron.
The 10” and 12” Iron-Cleer filters have been tested by WQA against NSF/ANSI 42 for the reduction of iron. The concentration of

iron in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the

system as specified in NSF/ANSI 42.
Testing was performed under laboratory conditions, actual results may vary.
Performance Indicator: If water flow decreases or a noticeable odor returns, the filter should be reconditioned. If conditions do not

improve, contact your local Culligan Man. He can determine if your filter requires servicing.
Regeneration Frequency: Regeneration frequency will vary depending upon water conditions.
Refer to your Installation and Operation Instructions, Parts List and Printed Warrantees for more specific product information.

To avoid contamination from improper handling and installation, your system should only be installed and serviced by your

Culligan Man. Performance may vary based on local water conditions. The substances reduced by this product are not

necessarily in your water.

Buyer Signature

Date

Seller Signature

Date

16