Amico NFPA Triplex RVL Modular Stack Mount User Manual
Page 19

www.amico.com
3.
Panel designed with selectable options to fully match applications
a.
All system settings shall be user adjustable and accessible with the system in operation and
the control panel door closed (password protected).
b.
Adjustments can be made to pressure settings to match the customers’ requirements.
c.
All alarms to require manual reset.
Specifier: select the section below reflecting the preferred technology:
Standard alarms shall open on failure with local audible and visual alarms with dry contacts for the following
conditions:
4.
OIL-LESS CLAW PUMP
a.
Lag pump in use
b.
Main transformer failure
c.
Motor
overload
d.
High discharge air temperature
e.
High inlet vacuum
4.
LUBRICATED ROTARY VANE PUMP
a.
Lag pump in use
b.
Main transformer failure
c.
Motor
overload
d.
High discharge air temperature
e.
Low oil level
4.
DRY ROTARY VANE PUMP
a.
Lag pump in use
b.
Main transformer failure
c.
Motor
overload
d.
High discharge air temperature
4.
WATER-SEALED LIQUID RING VACUUM PUMP
a.
Lag pump in use
b.
Main transformer failure
c.
Motor
overload
d.
High water temperature
17
- NFPA Triplex RVD Modular Stack Mount NFPA Triplex CCD Modular Stack Mount NFPA Quadruplex RVL Modular Stack Mount NFPA Quadruplex RVD Modular Stack Mount NFPA Quadruplex CCD Modular Stack Mount NFPA Duplex RVL Vertical Tank Mount NFPA Duplex RVL Modular Stack Mount NFPA Duplex RVL Horizontal Tank Mount NFPA Duplex RVD Vertical Tank Mount NFPA Duplex RVD Modular Stack Mount NFPA Duplex RVD Horizontal Tank Mount NFPA Duplex CCD Vertical Tank Mount NFPA Duplex CCD Modular Stack Mount NFPA Duplex CCD Horizontal Tank Mount