ADS Environmental Services PrimeProbe2 QR 775016 A0 User Manual

Page 32

background image

PrimeProbe2 User Manual

28

#2 IMP +/-

Pulse on N.2 for net flow

Sign

Flow direction output

Range

Range Indication output

Max. Al+

Flow exceeds Maximum Threshold+

Max Al-

Flow exceeds Minimum Threshold -

Max +/-

Flow exceeds Net threshold

Min Al+

Flow below Minimum Threshold +

Min Al -

Flow below Minimum threshold -

Min Al +/-

Flow below net threshold

P. pipe

Empty Pipe alarm

Out2 =

Is set to the output functions of Out2 and is configured

using the same procedures as Out1.

Communications

Besides the integrated keypad of the PrimeProbe2 with remote display,
only one other communication protocol exists. This protocol, IF2, uses a
PrimeProbe-PC link cable (USB) for configuration. The user can also
configure the PrimeProbe2 using the PrimeWorks software with this
protocol.

Set this parameter to HTP for PrimeWorks communication.

Display

Language

Allows the user to select from among several

languages for the PrimeProbe2 display:

E = English

I = Italian

F = French

S = Spanish

T+ reset

Allows the user to reset the Forward Totalizer using the

keypad. Simply press Enter, and the Execute? message will
appear. HOLD Enter again, and a Done message will display.

P+ reset

Allows the user to reset the Partial fFrward totalizer.

Use the same procedure as described in T+ reset.

T- reset

Allows the user to reset the Reverse Totalizer. Use the

same procedure as described in T+ reset.

P- reset

Allows the user to reset the Partial Reverse Totalizer.

Use the same procedure as described in T+ reset.

D. Times

Allows the user to set the amount of time, since the

keypad was last used, before the display turns itself OFF. Enter
this value in seconds. To turn the display back ON, simply hold