Assemble RH Valve
Great Plains Manufacturing, Inc.
13
2012-08-30
401-828M
Assemble RH Valve
If fittings are pre-installed, check torque and continue at
“Update Left Hydraulics” on page 9.
See “Connector Identification” on page 18 for
reference information concerning hydraulic connections.
Refer to Figure 19
63. Select one each new:
and two
Thread an elbow
into each valve
port.
Orient the side elbow so that the MJIC end points
toward the actuator
end of the valve.
Orient the end elbow so that the MJIC end points
away from the side elbow.
64. Select one each new:
811-073C TE 3/4MJIC 3/4MJIC 3/4FJIC
Connect the FJIC end to the end elbow. Orient the
center MJIC port to point toward the actuator end of
the valve.
65. Select one new:
Connect the FJIC center port to the end MJIC port
of tee
. Orient the end MJIC port to point away
from the actuator end of the valve.
66. Secure all fittings to torque specifications.
Install RH Valve
Refer to Figure 20
67. Select the new RH valve assembly:
with fittings pre-installed (from step 63 through
step 66 if not shipped pre-assembled)
Orient the valve above the rod end of the aft RH
cylinder, with the actuator pointing toward machine
center, and the fitting tree with the tee
pointing to
machine rear.
68. Route new hose
under the aft cylinder. Connect
it to side elbow
69. Connect existing wing-to-wing hose
to the center
port of tee
70. Connect existing inner-to-outer hose
elbow
71. Secure all fittings to torque specifications.
Figure 19
RH Stroke Control Valve
34099
6
U
D
F
B
L
R
Figure 20
Updated RH Aft Rod End
34097
RH
D