52
Refer to Figure 60
6.
Check for excess wear on meter slide (1).
Slight wear at the top corner is normal.
7.
If slide is not excessively worn, stop here. If it
is, continue with the following steps to re-
place.
Refer to Figure 61
8.
Remove retaining clip and pin from meter.
NOTE: Meter slide is spring loaded and the two
meter slide springs will be released when you pull
the pin. Use care not to lose pins and springs.
9.
Check removed pin for wear and replace if
worn.
Refer to Figure 62
10. Remove meter slide (1) with springs (2).
11. Place springs in new meter slide and install in
meter.
12. Reinstall seed meter wheel.
Figure 60
Meter slide location
18269
Retaining
clip
Figure 62
Meter slide and springs
18269
Figure 61
Meter slide retaining clip