Connect Sequence Valve
Sequence Valve Port Assignments
Connect Supply Hoses at Valve
42. Remove any caps from the two supply ports
(stamped “1” and “2” on the valve body). Remove
any plugs from one FJIC end of each supply
hose
. Connect the FJIC hoses ends to MJIC
ports 1 and 2. Do not use pipe sealant. See page 20
for torque specification.
Connect Cylinder Hoses at Valve
43. Remove any caps from the four rear ports (stamped
“C1” through “R2” on the valve body). Remove any
plugs from one FJIC end of each marked cylinder
hose. Connect the FJIC hose ends marked C1
through R2 to MJIC valve ports stamped C1 through
R2. Do not use pipe sealant.
Port Stamp
Function
1
Supply
a
a Either port 1 or port 2 may be connected to the Extend or
Retract side of a tractor remote, as long as the other port is
connected to the Retract or Extend port of that same remote.
2
Supply
a
C1
Left Cylinder Rod End
C2
Right Cylinder Rod End
R1
Left Cylinder Base End
R2
Right Cylinder Base End
Note: The port stampings “C” and “R” are arbitrary.
In particular, “R” does not mean rod or retract.
Figure 13