Appendix, Finger meter brush adjustment, Appendix finger meter brush adjustment – Great Plains YP1630F-1670 Material Rate User Manual
Page 41
Great Plains Manufacturing, Inc.
39
2012-12-04
401-832B
Appendix
Finger Meter Brush Adjustment
The brush reduces or eliminates “doubles” (delivering
two seeds per finger), but if set too aggressively can
cause “skips” (delivering no seed on some fingers). As
needed, adjust for minimal doubles and skips.
Refer to Figure 17
The adjustable brush provides additional flexibility to
accommodate a wide range of seed sizes. Use lever
to gently rotate the brush into position.
The settings range from 1 to 5 with detents at each half
step, for a total of 9 detents. Although the numbers are
molded into the meter housing, only “1” and “5” may be
visible.To ensure consistency, rotate the lever fully
counter-clockwise “1”, and count detents as you advance
it to the desired setting.
Use the general guidelines in the table below to adjust
the brush position to your seed size and shape. The
numbers listed correspond to the numbers printed on the
outer housing of your meter.
If there is a decal on your meter, its units are in pounds
per 80 000 seed bag. The table below includes seeds
per pound and seeds per kilogram.
Seed Shape
Bag Weight (80 000 seeds)
Seeds Per kg
Seeds Per Pound Brush Setting
flats
15.9 kg (35 pounds)
5066 or less
2300 or less
2
flats
15.9 kg (35 pounds)
5066 or more
2300 or more
3
flats
20.4 kg (45 pounds)
3920 or less
1780 or less
1
flats
20.4 kg (45 pounds)
3920 or more
1780 or less
2
rounds
15.9 kg (35 pounds)
5066 or less
2300 or less
4
rounds
15.9 kg (35 pounds)
5066 or more
2300 or more
5
rounds
20.4 kg (45 pounds)
3920 or less
1780 or less
3
rounds
20.4 kg (45 pounds)
3920 or more
1780 or more
4
rounds
25.0 kg (55 pounds)
3194 or less
1450 or less
2
rounds
25.0 kg (55 pounds)
3194 or more
1450 or more
3
rounds
29.5 kg (65 pounds)
2709 or less
1230 or less
1
rounds
29.5 kg (65 pounds)
2709 or more
1230 or more
2
Note: These instructions describe the current finger
pickup meter shipped with new Great Plains
planters, which has an integrated adjustment lever
for the brush. If you have added pre-existing finger
meters after purchase, there is some chance that
you may have the previous model meter, adjusted
by screwdriver rather than lever. If so, rely on
counting detents to determine the setting. Not all
have 9 detents.
Figure 17
Finger Meter Brush Lever
25458
L
L