Test procedure – LaMotte AT Visual Series Water Softener Demo Kit User Manual
Page 16
16
Retain this
sample if
Total Residual
and Combined
Chlorine are to
be determined.
(Steps 8-12)
Chlorine • CODE 4-3006-01
Water for cities and communities is usually sanitized. Even waters that come from clean sources, protected
watersheds, reservoirs, and deep wells are commonly sanitized to assure safety. Chlorine is most commonly
used because it is effective against a wide range of microorganisms, its cost is low, and the methods of applying
it have been well developed.
*WARNING: Reagents marked with an * are considered to be potential health hazards. To view or print a Mate-
rial Safety Data Sheet (MSDS) for these reagents go to www.lamotte.com. To obtain a printed copy, contact
LaMotte by e-mail, phone or fax.
TEST
PROCEDURE
Fill a test tube
(0106) to the
10 mL line
with the water
sample.
Insert test tube into
Octa-Slide 2 Viewer.
Match sample color
to a color standard.
Record ppm
Free
Available
Chlorine.
Cap and mix
until tablet
dissolves.
Cap and mix
until tablet
disintegrates.
Add one
*Chlorine DPD
#1R Tablet
(69999A).
Add one
*Chlorine DPD
#3 Tablet (6905)
to the sample
from Step 6.
Free Available Chlorine
Total Residual Chlorine & Combined Chlorine
Insert DPD
Octa-Slide 2 Bar
(3401-01) into
the Octa-Slide 2
Viewer (1101).
Match sample color
to a color standard.
Record ppm
Total
Residual
Chlorine.
1.
2.
3.
4.
5.
6.
7.
9.
8.
11.
10.
12.
Insert DPD
Octa-Slide 2 Bar
(3401-01) into
the Octa-Slide 2
Viewer (1101).
Insert test tube into