beautypg.com

Exide Technologies V19CIL5200ULS User Manual

Page 15

background image

Sales •• Service •• Recycling 888.563.6300 in the USA 800.2682698 in Canada

14

If less than 3.0VPC, current will flow for 5 minutes and the charge will be

suspended for 5 minutes. The cycle is repeated until the battery voltage is

greater than 1.70 VPC at the end of the 5-minute rest period.

If the battery voltage is greater than 1.70 VPC at the end of the 5-minute rest

period, the battery recovery mode will cease and charge will start from stage 1

with smart start disabled.

If 3.0 VPC is reached within the 5 minutes of charge, the charge will be

suspended equal to the ‘on’ time, maximum of 5 minutes. During this period

the display will show ‘Lobt’. During the 5-minute off period the display will

show the battery volts per cell alternating with ‘Lobt’.

11.9 DELAYED START OF CHARGE

A charge delay can be set in the service mode. The time is 0 to 48 hours in 1-hour

steps; this is permanently set for every charge cycle.

The display will show ‘dELy’ and alternate with the time remaining before charge

starts.

11.10 BATTERY COOLDOWN OPERATION STAGE

The cool down period begins after charge termination and is equal to the time spent

on charge.

During the cool down period, the green LED will flash and the display will show

‘CooL’ alternating with the remaining cool down time. The FUNCTION button can

select charge information and display this momentarily.

Once the cool down period is complete, the charger will illuminate the green LED

and enter the refresh stage.

If the battery is disconnected before completion of the cool down period, the

countdown will cease and the display will show F19.

If equalize is activated during cool down, the cool down timer will be suspended until

Equalize is complete, whereupon the cool down timer countdown will resume.

11.11 REFRESH CHARGE STAGE

The Refresh Charge activates every 24 hours after the standard charge cycle, if the

battery remains connected to the charger. The Refresh Charge stage lasts for 10

minutes and consists of Finish Rate or 19% of the maximum output current.

The 24-hour refresh delay starts after termination of recharge or Equalize. During

the refresh off period the display will show ‘rEdy’. The green LED will remain

illuminated. The FUNCTION button can select charge information.

Sales • Service • Recycling 888.563.6300 in the USA 800.268.2698 in Canada