Environmental requirements, Specifications, Environmental requirements -3 specifications -3 – Compaq M100 User Manual
Page 43

60001024, Third Edition
Installing the Omvia Media Server M130
3-3
About the M130
Environmental Requirements
To operate the system efficiently and safely, install and maintain the
Omvia Media Server M130 in a room with the appropriate temperature
and humidity.
The recommended location for the system is an office environment with
low dust content and an effective cooling and ventilation system. Install
the system within 5 feet of electrical outlets. A typical location is in the
room containing centralized telephone cabling, or near the PBX used by
the system.
Specifications
The environmental, dimension, and power input specifications for the
M130 are listed below:
Equipment Installation
Do not install the equipment in direct sunlight. Direct
sunlight can cause the system to overheat.
Table 3-1. M130 Specifications
Specification
Properties
Storage Environment
-20° C to 60° C or -4° F to 140° F
10% to 95% non-condensing humidity
Operating Environment
10° C to 35° C or 50° F to 95° F
10% to 90% humidity
Dimensions
16.75” W x 21.5” D x 1.67” H
Weight
24.58 lbs.
Range Line Voltage
100 to 240 VAC
Nominal Line Voltage
100 to 120 VAC/220 to 240 VAC
Rated Input Current
2A (100 to 120 VAC) to 1A (200 to 240 VAC)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
200W