2.1.4. TIME OF DAY START

The time-of-day start feature allows the operator to delay the start of charge until a particular time of day.

This might be desired to reduce peak energy surcharges if the charger were ready to start during a peak

energy period. The time-of-day start could be set to keep the ch arger from st arting until af ter the pea k

period ends.
Press the ‘SET FUNC.’ key to enter the prog ramming mode. The DATA di splay will show ‘Set’. Pr ess

‘START TIME’. The MODE display will then sho w ‘TS’ for time-of-day st art. The DATA display will show

tod Str=’ and the time of day in 24 hour format. The UNITS display will show ‘HM’ to indicate the time-of-

day is expre ssed in hou rs and minute s. The parameter is chang ed by enterin g a new valu e using th e

numeric keys on the keyp ad. Data entry is from lef t to right. The digit being edited is highlighted. If more

than four digits are ente red, the lef t-most digits scroll off the lef t end of the DA TA display. If an incorre ct

number is keyed in, press 0 four times to scroll the bad number off the display and continue entering the

correct value. (Note that if no keys are pressed within about 8 seconds, the programming mode will time-

out and t he control will return to th e normal ‘OK 0 A’ display.) After the time -of-day has been entered,

press ‘ENTE R’ to save it . The display will show ‘OK yes OK’ to confirm the n ew del ay time was

accepted. The control will then return t o the no rmal ‘OK 0 A’ display. To de-activate time-of-day start,

enter ‘99.99’ for the start time. Note that entering ‘0.00’ for the start time will cause the charger to st art at

midnight.

2.1.5. SETTING TIME OF DAY

In order to use the Time of Day Start feature, the current time of day must be set correctly.
Press the ‘SET FUNC.’ key to enter the prog ramming mode. The DATA di splay will show ‘Set’. Pr ess

‘CLOCK’. The MODE display will then show ‘TD’ for time-of -day. The DATA display will show ‘tod=’ and

the time of day in 24 hour form at. The UNITS displ ay will show ‘HM’ to indicate the time-of-day is

expressed in hours and minutes. The parameter is changed by e ntering a new value u sing the num eric

keys on the keypad. Data entry is from left to right. The digit being edited is highlighted. If more than four

digits are entered, the left-most digits scroll off the left end of the DA TA display. If an incorre ct number is

keyed in, press 0 four tim es to scroll the bad number off the di splay and continue entering the corre ct

value. (Note that if no keys are pressed within about 8 seconds, the programming mode will time-out and

the control will return to t he normal ‘ OK 0 A’ di splay.) After the time-of-day has been e ntered, press

‘ENTER’ to save. The display will show ‘OK yes OK’ to confirm th e new time was a ccepted. The control

will then return to the normal ‘OK 0 A’ display.

2.1.6. EMERGENCY STOP

To manually terminate the charge cycle, press ‘ON/OFF’. The charge will immediately stop. The MODE

display will then sh ow ‘OF’ for ‘of f’ and the DA TA display will sh ow ‘OFF ‘. Pressing ‘ON/OFF’ while the

DATA display shows ‘OFF ‘ causes the charge to resume.


2.1.7. SETTING BATTERY COOL DOWN TIME

A time period can be set to allow a battery to cool down after being charged. Press the ‘SET FUNC’ key to

enter th e p rogramming m ode. The DATA di splay will sho w ‘ Set’. Press ‘ COOL DOWN’ . The M ODE

display will then show ‘CT’ for cool down time. The DATA display will show ‘CooL dn For=’ and the hours

and minutes of cool down time currently set. The parameter is changed by entering a new value using the

numeric keys on the keyp ad. Data entry is from lef t to right. The digit being edited is highlighted. If more

than four digits are ente red, the lef t-most digits scroll off the lef t end of the DA TA display. If an incorre ct

number is keyed in, press 0 four times to scroll the bad number off the display and continue entering the

correct value. (Note that if no keys are pressed within about 8 seconds, the programming mode will time-

out and the control will return to the n ormal ‘OK 0 A’ display.) Enter the cool down time in hours an d

minutes (00. 00 to de -activate co ol down tim e) an d p ress ‘ENTER’ to save it. The di splay will sho w

OK yes OK’ to confirm t he ne w dela y time was a ccepted. The control will then ret urn to the normal

OK 0 A’ display.