Exide Technologies GB4109 User Manual
Page 20
Sales x Service x Recycling 888.563.6300 in the USA 800.268.2698 in Canada
17
III. Charger
Lifetime
History
While in the
Main Menu, press the up/down (q/r) keys until the Lifetime Summary screen
appears.
M
A
I
N
M
E
N
U
:
L
I
F
E
T
I
M
E
S
U
M
M
A
R
Y
E
X
I
T
E
N
T
E
R
Pressing the “
ENTER” key will access the selected menu. The charger lifetime operational
summary screen will then appear.
F
I
R
S
T
C
H
A
R
G
:
0
7
/
1
9
/
0
7
C
H
R
G
H
O
U
R
S
:
1
2
3
4
A
M
P
H
O
U
R
S
:
1
2
3
4
5
K
W
H
O
U
R
S
:
1
2
3
4
The above variables allow users to verify charger usage since installation and compare usage of
a specific charger versus others in the vicinity or in the plant.
IV. CHARGER MODEL AND SERIAL NUMBER
While in the
Main Menu, press the up/down (q/r) keys until the Charger Model screen appears.
M
O
D
E
L
:
P
C
H
G
-
L
V
-
6
0
0
4
8
M
F
G
I
D
:
2
0
0
5
0
1
0
0
0
1
M
F
G
D
A
T
E
:
0
7
/
1
9
/
2
0
0
7
R
E
V
I
S
I
O
N
:
1
.
1
0
The charger model number, ID, manufacturing date and firmware revision are shown for
reference.
V. RECOVERY CYCLE FOR SULFATED BATTERIES
One of the unique features of this charger is the ability to activate a long safe recovery cycle for
sulfated batteries. This can be easily done by accessing the recovery cycle screen and starting a
recovery cycle for a given battery.
1. While
in
the
Main Menu, press the up/down (q/r) keys until the Recovery Cycle for
Sulfated Battery screen appears.