TECHNICAL SERVICE MANUAL
WARNING!
Persons with surgical implants of a metallic
or electronic nature should avoid working on
pump – especially the inner magnet assembly.
This information must be read fully before
beginning any maintenance or repair of the
pump. All maintenance or repair must be
done by SUITABLY TRAINED or qualified
persons only.
FIGURE 1
MoDEL LS8124A-325
CoNTENTS
INTRoDUCTIoN
The illustrations used in this manual are for identification
purposes only and cannot be used for ordering parts. Obtain
a parts list from the factory or a Viking® representative.
Always give the complete name of a part, the part number
and material, along with the model number and serial number
of the pump when ordering repair parts. The unmounted
pump or pump unit model number and serial number can be
found on the nameplate secured to the pump.
This manual refers only with Series 8124A, 8123A and 8127A
universal magnetic drive pumps. Refer to Figures 1 through
17 for general configuration and nomenclature used in this
manual. Pump specifications and recommendations are
listed in Catalog Section 635.
In the Viking model number system, the basic size letters (K,
KK, L, etc.) are combined with the series number (8124A,
8123A, 8127A) indicating basic pump external construction
material, see
Figure 3.
Introduction . . . . . . . . . . . . . . . . . . . . . . . .
1
Special Information . . . . . . . . . . . . . . . . . . . .
1
Safety Information. . . . . . . . . . . . . . . . . . . . .
2
Maintenance . . . . . . . . . . . . . . . . . . . . . . .
3
Model Number System . . . . . . . . . . . . . . . . . .
3
Parts Identification Drawings . . . . . . . . . . . . . . .
4
Disassembly of Pump. . . . . . . . . . . . . . . . . . .
5
Disassembly / Assembly of Bracket Bearings. . . . . . .
6
Installation of Bushings . . . . . . . . . . . . . . . . . .
7
Assembly of Pump . . . . . . . . . . . . . . . . . . . .
7
Pump Rotation . . . . . . . . . . . . . . . . . . . . . .
9
Adjusting End Clearance . . . . . . . . . . . . . . . . .
9
Pressure Relief Valve Instructions . . . . . . . . . . .
10
Troubleshooting . . . . . . . . . . . . . . . . . . . . .
11
Warranty . . . . . . . . . . . . . . . . . . . . . . . .
12
SPECIAL INFoRMATIoN
DANGER !
Before opening any Viking pump liquid cham-
ber (pumping chamber, reservoir, relief valve
adjusting cap fitting etc.) Be sure:
1. That any pressure in the chamber has been
completely vented through the suction
or discharge lines or other appropriate
openings or connections.
2. That the driving means (motor, turbine,
engine, etc.) has been “locked out” or made
non- operational so that it cannot be started
while work is being done on pump.
3. That you know what liquid the pump has been
handling and the precautions necessary to
safely handle the liquid. obtain a material
safety data sheet (MSDS) for the liquid to be
sure these precautions are understood.
Failure to follow above listed precautionary
measures may result in serious injury or death.
ROTATION: Viking Mag Drive® pumps are designed to run
in either direction. See
“Pump Rotation”, page 9.
PRESSURE RELIEF VALVES:
1. Viking pumps are positive displacement pumps and
must be provided with some sort of pressure protection.
This may be a relief valve mounted directly on the pump,
an inline pressure relief valve, a torque limiting device or
a rupture disk. Do not rely on decoupling of magnets for
protection from over pressure; this may result in damage
to the magnets, pump, or other equipment.