CW[nn]
Moves the actuator in a clockwise direction,
where nn = 1 to NP (see also NP command)
Modes available:
All (with restrictions – in two position modes, nn is not allowed)
Examples (multiposition, mode 3)
Command:
CW
Moves the actuator clockwise one position
Command:
CW3
Moves the actuator clockwise position 3
Example (two position, modes 1 and 2)
Command:
CW
Moves the actuator from position B to position A. If the actuator
is already in Position A, the command is ignored.
DT[nnnnn]
Sets a delay interval before the actuator automatically returns to its previous position,
where nnnnn = 0 – 65535 (milliseconds) (See also TT command)
Modes available:
Two position (1 and 2)
Examples
Command:
DT
Returns
DTnnnn [0x0D] (nnnn = current delay setting)
Command:
DT0
Sets the delay time to 0 and disables the TT command
Command:
DT1000
Sets the delay timer to 1000 milliseconds (1 second)
GO[nn]
Tells the actuator to go to position nn,
Where nn = 1 to NP (multiposition, mode 3)
= ‘A’ or ‘B’ (two position, modes 1 and 2)
(See also NP and SM commands)
Modes available:
All (see below)
Examples (two position, modes 1 and 2)
Command:
GO
Toggles the actuator to the other position
Command:
GOB
Moves the actuator from position A to position B
Examples (multiposition, mode 3)
Command:
GO
Advances the actuator to the next position
Command:
GO3
Moves the actuator to position 3 in the direction set by the
SM command
HM
Moves the actuator to position 1. If the actuator is already in position 1, the command
is ignored.
Modes available:
Multiposition (3)
Example
Command:
HM
Moves the actuator from the current position to position 1
Optional Serial Interface