8. Route the input power cable down through the bushing

closest to the rear of the Ultima 150 Power Supply in-
stalled in Step 5 above.

9. Connect the three AC wires from the input power cable

to terminals 1, 2 and 3 of the left hand terminal block in
the Transformer Module.

10. Connect the ground wire in the input power cable to

the ground stud on the base of the Transformer Mod-
ule.

11. In the Transformer Module route the four wires, one

green/yellow and three black wires (labeled 1, 2 &
3), connected to the right hand terminal block up
through the bushing closest to the front of the Ul-
tima 150 Power Supply installed in Step 5 above.

Transformer Module

575 VAC

Input

Power Cable Routing
(Inside Power Supply)

Ultima-150 Power Supply

PIL

OT

AR

C

PR

EV

IEW

ON

CU

RR

EN

T

SE

T

A

A

CU

RR

EN

T

0.5-

15

5-1

50

PR

EV

IEW

AR

C

VO

LTS

A /

V

A

LIM

IT

A

PA

NE

L

RE

MO

TE

A

CO

OL

PIL

OT

DC

GA

S

TEM

P

AC

A

V

RA

NG

E

Made In

US

A

PL

AS

MA

SH

IEL

D

Figure 1 Input Power Cable Routing

12. Lift the Ultima 150 Power Supply enough to slide it

forward so that the three holes in both sides of the
Ultima 150 Power Supply base line up with the three
holes in each side of the Transformer Module.

13. Install one each of the 1/4-20 bolts (supplied) into

each of the six holes. These are self threading bolts
and may require a little extra force the first time they
are installed.

14. Pull the excess slack in the input power cable up out of

the bushing in the Ultima 150 Power Supply base and
out through the strain relief. Tighten the strain relief.

15. Pull the three black and one ground wire up through

the bushing in the Ultima 150 Power Supply base.

16. Connect the ground wire to the ground stud in the

base of the Ultima 150 Power Supply.

17. Connect the black wires to the top studs on the rear of

the front panel Ultima 150 Power Supply ON/OFF cir-
cuit breaker per the following:

NOTE

Location of studs are viewed looking at the rear of
the circuit breaker.

a. Black wire labeled '1' to top left stud.

b. Black wire labeled '2' to top center stud.

c. Black wire labeled '3' to top right stud.

18. Replace the cover on the Ultima 150 Power Supply.

NOTE

Every effort has been made to provide com-
plete and accurate information in this manual.
However, the publisher does not assume and
hereby disclaims any liability to any party for
any loss or damage caused by errors or omis-
sions in this Manual, whether such errors re-
sult from negligence, accident, or any other
cause.

Manual 0-2498 Instruction Sheet 11/95