beautypg.com

Stainless steel 200a n, Plasma / h, O shield – Tweco XT-301 Torch Data for Distributor Use w- Auto-Cut 200 AF User Manual

Page 15

background image

Torch Data

8-15

Manual 0-4806 Rev. AF

Electrode

Shield Cap

Tip

Shield Gas

Distributor

Plasma Gas

Distributor

Cartridge

Shield Cup

This Art Is For Reference ONLY

Art # A-07958_AB

Shield

Cap

Shield Gas

Distributor

Tip

35-1039

35-1273

35-1064

Plasma (N

2

)

Shield

(H

2

O)*

(ga)

(in)

inch

(PSI)

(Ball)

Volts

(in)

±0.005

(ipm)

(in)

(sec)

(in)

1/2

0.500

90

5

170

0.160

90

0.300

0.4

0.117

5/8

0.625

90

5

173

0.200

75

0.300

0.5

0.128

3/4

0.750

110

5

175

0.250

60

0.300

0.6

0.132

7/8

0.875

110

5

180

0.250

50

0.300

0.7

0.141

1

1.000

110

5

185

0.300

40

0.350

1.0

0.151

1.25

1.250

110

5

189

0.350

30

0.163

1.5

1.500

110

5

202

0.350

20

0.175

1.75

1.750

110

5

205

0.400

15

0.180

Plasma (N

2

)

Shield

(H

2

O)*

(Bar)

(Ball)

Volts

(mm)

±0.1

(mm/min)

(mm)

(sec)

(mm)

6.2

5

169

4.1

2300

7.6

0.4

2.9

6.2

5

173

5.0

1950

7.6

0.5

3.2

7.6

5

178

6.4

1450

7.6

0.6

3.4

7.6

5

185

7.6

1000

8.9

1.0

3.8

7.6

5

190

8.9

750

4.1

7.6

5

202

8.9

500

4.4

7.6

5

205

10.2

380

4.6

* Pressure of the water supply line should be regulated at 55 PSI / 3.4 Bar by customer pressure regulator.
Note1: Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the
ohmic sensing circuit.

Note2: Water source used for shield must be demineralized.

Edge Start

Edge Start

15

20

44

Edge Start

Edge Start

38

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Edge Start

Edge Start

35-1046

35-1089

35-1020

35-1016

Shield Cup

Plasma Gas

Distributor

Electrode

Cartridge

32

Material

Thickness

Cut Flows / Pressures

Arc

Voltage

Torch

Working

Height

(mm)

12

25

Kerf Width

@ Rec.

Speed

Stainless Steel
200A
N

2

Plasma / H

2

O Shield

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.
Requires CCM version 3.4 or later. Requires GCM version 3.2 or later.

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec.

Speed

Material

Thickness

Cut Flows / Pressures

Arc

Voltage

Torch

Working

Height