Stainless steel 100a n, Plasma / h, O shield – Tweco XT-301 Torch Data for Distributor Use w- Auto-Cut 200 AF User Manual
Page 12
Torch Data
8-12
Manual 0-4806 Rev. AF
Stainless Steel
100A
N
2
Plasma / H
2
O Shield
Plasma
(N
2
)
Shield
(H
2
O)
(ga)
(in)
inch
(PSI)
Ball *
Volts
(in)
±0.005
(ipm)
(in)
(sec)
(in)
10
0.141
100
5
160
0.125
160
0.200
0.000
0.074
3/16 0.188
100
5
157
0.125
100
0.250
0.300
0.080
1/4
0.250
100
5
155
0.125
60
0.250
0.300
0.086
3/8
0.375
100
5
159
0.125
50
0.250
0.300
0.087
1/2
0.500
100
5
169
0.130
35
0.300
0.500
0.100
5/8
0.625
100
5
175
0.140
30
0.300
0.600
0.110
3/4
0.750
100
5
177
0.150
25
0.125**
Plasma
(N
2
)
Shield
(H
2
O)
(Bar)
Ball *
Volts
(mm)
±0.1
(mm/min)
(mm)
(sec)
(mm)
6.9
5
161
3.2
4810
4.5
0
1.8
6.9
5
159
3.2
3530
5.5
0.1
1.9
6.9
5
157
3.2
2400
6.4
0.3
2.1
6.9
5
155
3.2
1750
6.4
0.3
2.2
6.9
5
157
3.2
1390
6.4
0.3
2.2
6.9
5
160
3.2
1210
6.5
0.3
2.3
6.9
5
167
3.3
970
7.3
0.5
2.5
6.9
5
173
3.5
800
7.6
0.6
2.7
6.9
5
178
3.9
600
3.2
Edge Start
Edge Start
** Not measured, extrapolated value.
* Ball setting for shield water is set using a line pressure of 55 PSI / 3.8 Bar
15
20
6
8
10
12
(mm)
3
4
5
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
Kerf Width
@ Rec.
Speed
Material
Thickness
Cut Flow Pressures
Arc
Voltage
Torch
Working
Height
NOTE: Ohmic height sensing is not recommended with water shield.
Water on the plate interferes electrically with the ohmic sensing system.
100A Stainless Steel (N
2
/H
2
O)
Material
Thickness
Cut Flow Pressures
Arc
Voltage
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
Kerf Width
@ Rec.
Speed
35-1053
35-1041
35-1089
Cartridge
35-1020
Shield Cup
35-1016
Plasma Gas Distributor*
Shield Gas Distributor
Shield Cap
Art # A-04939
35-1034
35-1272
Tip
Electrode