Manual 0-4802 Rev. AJ
8-33
TORCH DATA
(ga)
(in)
inch
(PSI)
(Ball)
(PSI)
(Ball) (PSI)
Volts
(in)
±0.005
(ipm)
(in)
(sec)
(in)
1/2
0.500
20
100
90
5
55
168
0.250
110
0.300
0.3
0.120
5/8
0.625
20
80
100
5
55
170
0.300
105
0.350
0.5
0.126
3/4
0.750
20
80
100
5
55
175
0.300
90
0.350
0.6
0.127
7/8
0.875
20
80
100
5
55
180
0.300
75
0.350
0.8
0.133
1
1.000
20
80
100
5
55
194
0.350
50
0.400
1.0
0.144
1.25
1.250
20
80
100
5
55
208
0.400
25
0.450
2.0
0.180
1 1/2
1.500
20
80
100
5
55
210
0.400
20
0.500
3.000
0.197
1 3/4
1.750
20
80
100
5
55
212
0.400
18
0.201
2
2.000
20
80
100
5
55
215
0.400
12
0.204
(Bar)
(Ball) (Bar) (Ball) (Bar)
Volts
(mm)
±0.1
(mm/min)
(mm)
(sec)
(mm)
1.4
100
6.3
5
3.8
167
6.3
2900
7.6
0.3
3.0
1.4
80
6.9
5
3.8
170
7.5
2700
8.9
0.5
3.2
1.4
80
6.9
5
3.8
176
7.5
2200
8.9
0.6
3.3
1.4
80
6.9
5
3.8
194
8.9
1300
10.2
1.0
3.6
1.4
80
6.9
5
3.8
208
10.2
630
11.4
2.0
4.6
1.4
80
6.9
5
3.8
210
10.2
500
12.7
3.0
5.0
1.4
80
6.9
5
3.8
212
10.2
460
5.1
1.4
80
6.9
5
3.8
215
10.2
300
5.2
* Pressure of the water supply line should be regulated by customer pressure regulator.
Note1: Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the
ohmic sensing circuit.
Note2: Water source used for shield must be demineralized.
Aluminum
200A
N
2
Plasma / H
2
O Shield
BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.
Requires CCM version 3.4 or later. Requires GCM version 3.2 or later.
50
Edge Start
32
38
44
Edge Start
12
15
20
25
Kerf Width
@ Rec.
Speed
Plasma (N
2
)
Shield
(H
2
O)*
(mm)
Edge Start
Material
Thickness
Pre Flow
Pressure
(N
2
)
Cut Flow Rates / Pressures
Arc
Voltage
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
Kerf Width
@ Rec.
Speed
Plasma (N
2
)
Shield
(H
2
O)*
Edge Start
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
Material
Thickness
Pre Flow
Pressure
(N
2
)
Cut Flow Rates / Pressures
Arc
Voltage
22-1043
22-1089
22-1022
22-1015
22-1049
22-1284
22-1067
Plasma Gas
Distributor
Electrode
Cartridge
Shield
Retainer
Shield Cap
Shield Gas
Distributor
Tip
Cartridge
Electrode
Shield
Shield Gas
Distributor
Tip
Plasma Gas
Distributor
Shield Retainer
Art # A-07917_AC
This Art Is For Reference ONLY