Stainless steel 200a n, Plasma / h, O shield – Tweco XT-300 Torch Data for Distributor Ultra-Cut 150 & 200 Power Supply AJ User Manual
Page 21

Manual 0-4801 Rev. AJ
8-21
TORCH DATA
(ga)
(in)
inch
(PSI)
(Ball) (PSI) (Ball) (PSI)
Volts
(in)
±0.005
(ipm)
(in)
(sec)
(in)
3/8
0.375
20
80
90
5
55
155
0.160
95
0.300
0.0
0.110
1/2
0.500
20
80
90
5
55
156
0.160
85
0.300
0.4
0.115
5/8
0.625
20
80
90
5
55
158
0.180
65
0.300
0.5
0.122
3/4
0.750
20
80
90
5
55
163
0.200
50
0.300
0.7
0.133
7/8
0.875
20
80
90
5
55
177
0.250
40
0.400
0.9
0.149
1
1.000
20
80
90
5
55
183
0.300
35
0.450
1.0
0.148
1 1/4
1.250
20
80
90
5
55
185
0.300
20
0.176
1 1/2
1.500
20
80
90
5
55
200
0.350
10
0.211
1 3/4
1.750
20
80
90
5
55
207
0.350
8
0.216
(Bar)
(Ball) (Bar) (Ball) (Bar)
Volts
(mm)
±0.1
(mm/min)
(mm)
(sec)
(mm)
1.4
80
6.3
5
3.8
155
4.1
2400
7.6
0.0
2.8
1.4
80
6.3
5
3.8
156
4.1
2000
7.6
0.4
2.9
1.4
80
6.3
5
3.8
157
4.4
1550
7.6
0.5
3.1
1.4
80
6.3
5
3.8
165
5.1
1100
7.6
0.7
3.4
1.4
80
6.3
5
3.8
183
7.6
900
11.4
0.9
3.7
1.4
80
6.3
5
3.8
185
7.6
500
4.5
1.4
80
6.3
5
3.8
200
8.9
250
5.4
1.4
80
6.3
5
3.8
206
8.9
200
5.5
* Pressure of the water supply line should be regulated by customer pressure regulator.
Note1: Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the
ohmic sensing circuit.
Note2: Water source used for shield must be demineralized.
Stainless Steel
200A
N
2
Plasma / H
2
O Shield
BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.
Requires CCM version 3.4 or later. Requires GCM version 3.2 or later.
Edge Start
Edge Start
25
32
44
Pre Flow
Pressure
(N
2
)
Edge Start
Edge Start
Edge Start
Edge Start
21-1022
21-1015
21-1049
21-1284
21-1067
Plasma Gas
Distributor
Electrode
Cartridge
Shield
Retainer
Shield Cap
Shield Gas
Distributor
Tip
21-1043
21-1089
Kerf Width
@ Rec.
Speed
Plasma (N
2
)
Cut Flow Rates /
Pressures
Arc
Voltage
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
Shield
(H
2
O)*
38
Material
Thickness
Pre Flow
Pressure
(N
2
)
Cut Flow Rates /
Pressures
10
12
(mm)
20
15
Material
Thickness
Pierce
Delay
Kerf Width
@ Rec.
Speed
Plasma (N
2
)
Shield
(H
2
O)*
Arc
Voltage
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
Cartridge
Electrode
Shield
Shield Gas
Distributor
Tip
Plasma Gas
Distributor
Shield Retainer
Art # A-07917_AC
This Art Is For Reference ONLY