beautypg.com

Quick wire trim unit – Tweco QWT-3 Quick Wire Trim Unit User Manual

Page 10

background image

QUICK WIRE TRIM UNIT

3-6

SM-QWT-3

inSTAllATion And opeRATion

CONDUCTOR

TUBE

NOzzLE/

WIRE

CUTTING BLADE

Figure 7: Conductor Tube/Wire and Blade

NOTE

The cutting blade can be rotated to extend the

life of the cutting blade. To rotate the cutting

blade, the following steps must be followed:

A. Remove the ¼”-20 shoulder screw located on

the under side of the mounting block of the

QWT-3 unit. Refer to Figure 8.

B. Loosen the 10-32 socket head cap screw on top

of the QWT-3 unit until the wire guide can be

removed. Refer to Figure 9.

10-32 SOCKET HEAD

CAP SCREW

WIRE GUIDE

Figure 9: Location of the 10-32 Socket Head Cap Screw

C. Rotate the cutting blade 180º so that the new

cutting edge is facing away from the QRC™-

2000 cleaning station. Be sure to position the

¼” (6,35mm) diameter hole over the dowel pin

located on the pivot arm. Refer to Figure 10.

Figure 10: Dowel Pin Alignment

DOWEL PIN

BLADE

WIRE

GUIDE

DOWEL

PIN

PIVOT

ARM

D. Place the wire guide back into position and

thread the ¼”-20 shoulder screw back into the

mounting block and secure.

E. Tighten the 10-32 socket head cap screw wrench

tight.

9. Activate the cleaning station such that the clamping

arm moves to the clamped position and then returns

to the unclamped position.

10. Move the robot arm away from the wire trim unit/

cleaning station.

11. Begin the welding process.

SHOULDER

SCREW

SHOULDER

SCREW

Figure 8: Shoulder Screw