SERVICE

5-8

Manual 0-4603

2. System is in protective interlock mode. (Torch parts are missing or loose.)

a. Release torch trigger, and set power supply ON / OFF switch to OFF (down). Open main disconnect switch.

Check torch parts. Replace parts as needed. Reinstall shield cup; hand - tighten it securely against the torch
head. Do not overtighten. Do not use tools. Close main disconnect switch. Set ON / OFF switch to ON (up)
position.

J.

Gas cycles on and off without torch switch being activated; AC indicator

Flashing; Gas indicator

ON; DC indicator

OFF

1. Torch tip or electrode missing

a. Shut off power supply. Remove shield cup, install missing part(s). Turn power supply ON / OFF switch to

ON (up).

K. No cutting output; Torch pilots; Gas flows; Fans operate; AC

, Gas

, and DC

indicator ON;

TEMP

indicator OFF

1. Work cable not connected to work piece, or connection is poor

a. Make sure that work cable has a proper connection to a clean, dry area of the workpiece.

2. Faulty Torch

a. Return for repair or have qualified technician repair.

3. Faulty components in unit

a. Return for repair or have qualified technician repair per Service Manual.

L. Torch cuts but not adequately

1. Incorrect setting of output current (A) control

a. Check and adjust to proper setting.

2. Torch consumables worn

a. Check torch consumables per Torch manual; replace as needed.

3. Work cable connection to work piece is poor

a. Make sure that work cable has a proper connection to a clean, dry area of the workpiece.

4. Torch is being moved too fast across workpiece

a. Reduce cutting speed.

5. Torch being dragged on work. ('Tip saver' circuit active) At output current settings greater than 40 amps, the power

supply automatically reduces current to 40 amps if the torch tip contacts the workpiece.

a. Lift torch off work.

6. Excessive oil or moisture in torch

a. Put RUN / RAPID AUTO RESTART / SET switch in SET (down) position. Hold torch 1/8 inch (3 mm) from

clean surface while purging and observe oil or moisture buildup (do not activate torch). If there are contami-
nants in the gas, additional filtering may be needed.