beautypg.com

Tweco C-35C CutSkill User Manual

Page 20

background image

SERVICE

5-2

Manual 0-4688

2. Poor Work Lead connection.

a. Check the connection of the Work Lead to the

work piece.

Make a clean work cable
connection to the work-
piece or cutting table

Work Cable
And Clamp

Art # A-04389

3. Current sensor or PWM PCB faulty.

a. Return to an authorized service center for re-

pair.

F. Air flows continuously and torch switch latch

button doesn't work properly.

1. Torch Switch Latch button on front panel faulty.

a. Return to an authorized service center for re-

pair.

2. Control PCB faulty.

a. Return to an authorized service center for re-

pair.