Section 2: specifications, Section 2: specifications -1 – Tweco 38 CutMaster User Manual
Page 15

Manual 0-2964
2-1
SPECIFICATIONS
SECTION 2: SPECIFICATIONS
15.75"
400 mm
10"
254 mm
21"
0.53 m
43 lb / 19.5 kg
A-03378
Art # A-03379
6"
150 mm
24"
0.6 m
6"
150 mm
6"
150 mm
Weight includes torch & leads, input power cord,
and work cable with clamp.
CAUTION
Provide clearance for proper air flow through
the power supply. Operation without proper
air flow will inhibit proper cooling and reduce
duty cycle.
Input Power
Input Power Cable
Output Current
Power Supply Gas Filtering Ability
Ambient Temperature
Duty Cycle
35%
60%
DC Voltage
78
89
Current
30A
22
Gas Type
Gas specifications
Maximum Input Gas Pressure
Operating Gas Pressure
Gas Flow Requirements
CE CutMaster 38 Power Supply Specifications
208-230 VAC (± 10%), Single-Phase, 50/60 Hz
Suitable for 208-230VAC, 20-Amp Single-Phase input power.
20-30 Amps, continuously variable
Particulates to 20 Microns
CE CutMaster 38 Power Supply Duty Cycle (Note 1)
104° F (40° C)
100%
n/a
n/a
SL 60 Torch Gas Requirements
Compressed Air
Clean, dry, oil-free (Note 2 )
125 psi / 8.6 bar
1. Duty Cycle is the percentage of time the system can be operated without overheating. Duty cycle
is reduced if primary input voltage (AC) is low or the DC voltage is higher than shown in this chart.
2. Air supply must be free of oil, moisture, and other contaminants. Excessive oil and moisture may
cause double-arcing, rapid tip wear, or even complete torch failure. Contaminants may cause poor
cutting performance and rapid electrode wear. Optional filters provide increased filtering capabilities.
65 psi / 4.5 bar
300 scfh / 141.5 lpm
Notes