5

START-UP

Pump air supply pressure should be regulated.

Open the fluid suction (IN) line valve, if necessary.

Open the fluid discharge (OUT) line valve, if necessary.

Start with air regulator at low pressure setting. Increase or decrease pressure to attain desired flow,
up to 60 PSIG (.41 MPa) at the pump.

Table 1: Consumption / Efficiency can be used to determine approximate air consumption.

Refer to Troubleshooting, Section 0, if pump fails to start.

ATTENTION: Prolonged periods of dry running will damage critical internal pump parts.

5.1

PERFORMANCE CHARTS

Pumping capacity is a function of air supply pressure and volume, suction head, suction line restrictions,
discharge head, discharge line restriction, and fluid specific gravity and viscosity.

Air Supply

Pressure

(PSIG)

Discharge Fluid

Pressure (PSIG)

Air Used

(SCFM)

Cycles

Per Minute

Displacement

IN

3

Per Cycle

20

0

3.9

170

10.4

20

10

2.8

105

9.3

30

0

5.6

190

10.5

30

15

4.0

120

9.4

40

0

7.0

198

10.5

40

20

5.4

125

9.6

50

0

8.4

205

10.5

50

25

7.2

130

9.7

60

0

10.2

208

10.6

60

30

8.4

128

9.4

Table 1: Consumption / Efficiency

NOTE: Specification to be used to size regulators and control valves.

Figure 5-1: Pressure & Capacity Chart