START-UP
Pump air supply pressure should be regulated.
Open the fluid suction (IN) line valve, if necessary.
Open the fluid discharge (OUT) line valve, if necessary.
Start with air regulator at low pressure setting. Increase or decrease pressure to attain desired flow,
up to 60 PSIG (.41 MPa) at the pump.
Table 1: Consumption / Efficiency can be used to determine approximate air consumption.
Refer to Troubleshooting, Section 0, if pump fails to start.
ATTENTION: Prolonged periods of dry running will damage critical internal pump parts.
5.1
PERFORMANCE CHARTS
Pumping capacity is a function of air supply pressure and volume, suction head, suction line restrictions,
discharge head, discharge line restriction, and fluid specific gravity and viscosity.
Air Supply
Pressure
(PSIG)
Discharge Fluid
Pressure (PSIG)
Air Used
(SCFM)
Cycles
Per Minute
Displacement
IN
3
Per Cycle
20
0
3.9
170
10.4
20
10
2.8
105
9.3
30
0
5.6
190
10.5
30
15
4.0
120
9.4
40
0
7.0
198
10.5
40
20
5.4
125
9.6
50
0
8.4
205
10.5
50
25
7.2
130
9.7
60
0
10.2
208
10.6
60
30
8.4
128
9.4
Table 1: Consumption / Efficiency
NOTE: Specification to be used to size regulators and control valves.
Figure 5-1: Pressure & Capacity Chart