Electrical application 482 e2, Tn4 gateway 482, Test – tekmar 482 tN4 Gateway User Manual

Page 5: Rs 232

background image

5 of 12

© 2012

D

482 - 01/12

Electrical Application

482 E2

L

G
N

Category 5 Cable (< 150 feet, 45 m)

2

tN4 Gateway 482

RS 232

Test

Power: 115 V ±10% 60 Hz 45 mA

Designed and assembled in Canada by
tekmar Control Systems Ltd.
tektra 1017-02

tN4 Bus 0

tN4 Bus 1

tN4 Bus 2

tN4 Bus 3

tN4 Bus 4

Power

Dat

e Code

not testing
testing
testing paused

off
red
red

Caution: Signal wiring must be rated at least 300 V.

H205

1A

Power

L

1

N

5

C1

1

6

tN4

3

C0

0

4

tN4

7

C2

2

8

tN4

9

C3

3

10

tN4

11

C4

4

12

tN4

Do not apply power

RS 232

Tx

Rx

To RS 232 Serial Port

Adapter

1

Reporting Enable

Power-On State

Off

On

Dual Zone Manager 337

Meets Class B: Canadian

ICES & FCC Part 15

Made in
Canada

Power Fuse: T15 A 250 V

15 A

Zone A1

Zone A2

Power

Zone Group Pump A

Zone A3

Zone B1

Zone B2

Zone B3

tN4

tektra 996-02

For product instructions, see brochure
Input Power: 115 V (ac) ±10% 60 Hz, 15.5 A
Relay Rating: 115 V (ac) 5 A
All Loads Using Input Power: 15 A

Caution! Disconnect All
Power before Opening

Limited power available, see wiring brochure

For product literature:
www.tekmarcontrols.com

Zone Group Pump B

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

20

H7005B

32

33

34

35

36

37

38

39

40

41

42

43

17

18

19

21

22

23

24

25

26

27

24 V (ac) Fuse: T2.5 A 250 V

28

29

30

31

On/Off

Zone Group

Pump A Delay

Zone Group

Pump A

Zone Group

Pump B Delay

Zone Group

Pump B

A1
A2
A3
B1
B2
B3
A1
A2
A3
B1
B2
B3

tN4

C

C

C

W

W

R

R

Pmp tN4

tN4

C

W

R

tN4

C

W

R

R

tN4

C

W

tN4

R

C

W

tN4

Input Power

Zn Grp Zn Grp

Zone A1

Zone A2

Zone A3

Zone B1

Zone B2

Zone B3

Zn Grp B

B

tNt

Zone A1

tNt

Zone A2

tNt

Zone A3

tNt

Zone B1

tNt

Zone B2

tNt

Zone B3

N

L

Pmp A

Pmp B

C

Vlv

C

Vlv

C

Vlv

C

Vlv

C

Vlv

C

Vlv

Supply /signal wires 90°C min.

51

52

53

54 55

56

57

58

59

60

61

62

63

64

65

Boiler

DHW

Setpoint

C

C2

tN4

C

Com Boil Mix Com Out

+

Opn Cls

Demand

Demand

24 V (ac)

Boil/Mix2

R

R

Mod (dc)

R

66

67

68

69

70

Primary

Mix Sys P1

10 A

max.

75

76

77

78

N

N

DHW

Variable Speed

71

72

73

74

Pump

Pump

N

Pump

N

Pump

tN4

H7008B

tN4 Boiler / Mix 2
Boil Sens Sup / Ret
Boiler On-Off / Mod
Off / tekmar Stager
Off / Flushing

Powered Output

Output 1 VA

Floating Output:

24 V (ac) 8 VA

Made in Canada

Meets Class B: Canadian
ICES & FCC Part 15

Test

Var. Pump Fuse

T2.5 A 250 V

Universal Reset Module 422

Item

Menu

tektra 991-03

Var. Pump: 115 V (ac) 2.5 A
Demands: 20 - 260 V (ac)
Relay Rating: 115 V (ac) 5 A

/

Do not apply power

2.5 A

Description: A Universal Reset Module 422 and Duel Zone Manager 337 are connected to a tN4 Gateway 482.

Refer to W 422 and W 337 wiring brochures for complete wiring schematic.