tekmarNet

®

Home Automation Protocol

Several leading home automation control companies
have worked together with tekmar and have created
software drivers for the tN4 Gateway 482 and tekmarNet

®

compatible products. These software drivers are available
from the home automation control company.

Refer to the 482 product page on tekmar’s website
http://tekmarcontrols.com/accessories/482.html

for details and a complete listing. The software drivers
allow easy integration of tekmarNet

®

products to the home

automation system.

If you have a home automation system that is not listed
on the tekmar website, you may create your own software
drivers. This will require advanced programming skills.

The tekmarNet

®

Home Automation protocol is available

on the tekmar website at:

http://tekmarcontrols.com/tha.html

Available Message Set:

NullMethod

FanPercent

NetworkError

TakingAddress

ReportingEnable

DeviceInventory

OutdoorTemperature

SetbackEnable

DeviceAttributes

SetbackState

ModeSetting

SetbackEvents

ActiveDemand

FirmwareRevision

CurrentTemperature

ProtocolVersion

HeatSetpoint

DeviceType

CoolSetpoint

DeviceVersion

SlabSetpoint

DateTime

Thermostat Addressing

The 482 uses the following format to address each
thermostat: Port:Bus:Thermostat Device

Each thermostat is able to display the Bus and Thermostat
Device on the LCD display. This is documented as the
‘tekmarNet Address’ in the thermostat data brochure.

Port Number

The leading digit is the Port number. This determined by
the wiring connection that the thermostat is wired to on
the 482.

482 tN4 Bus 0 (terminals 3 & 4) = 0

482 tN4 Bus 1 (terminals 5 & 6) = 1

482 tN4 Bus 2 (terminals 7 & 8) = 2

482 tN4 Bus 3 (terminals 9 & 10) = 3

482 tN4 Bus 4 (terminals 11 & 12) = 4

Bus Number

The second digit is the thermostat bus number. The bus
number is pre-determined by the wiring of the thermostat
to a boiler or mixing reset control water temperature bus.

In the event that no reset control is installed, the bus
number is 0.

The 406 tN4 bus numbering is dependent on the
WaterTemp and the Zone settings when configuring the
control.

WaterTemp

Zones

Tank

Bus

Mix

Bus

Boiler

Bus

T

1

T + M

1

2

T + B

1

2

T + MB

Mix

1

*

3

T + MB

Boil

1

2

**

* and ** thermostats on this bus are unable to communicate
to external systems.

Thermostat Device Number

The third and fourth digits indicate the thermostat
device number. The thermostat device number is a
two digit number that ranges from 01 to 24 and can be
determined from the thermostat address. To determine
the thermostat address, please consult the data brochure
for the appropriate thermostat.

Example 1
A thermostat with bus and thermostat device number of
b:01 is wired to a model 400 controller boiler bus and in
turn is wired to the 482 on port 0. This address is 0101.

Example 2
A thermostat with bus and thermostat device number of
b:24 is wired to a model 423 controller boiler bus and in
turn is wired to the 482 on port 0. This address is 0424.

Example 3
A group of thermostats are wired together to create a stand-
alone network. A thermostat with thermostat device number
15 is wired to the 482 on port 0. This address is 0015.

Control

Bus

Bus #

Control

Bus

Bus #

274

Boiler

1

420

Boiler

1

275

Boiler

1

421

Mix

1

400

Boiler

1

422

Mix1

1

401

Boiler 1

422

Boiler 2

402

Mix

1

422

Mix2

2

402

Boiler

2

423

Bus1

1

403

Mix

1

423

Bus2

2

403

Boiler 2

423

Bus3

3

423

Boiler

4