beautypg.com

2 operation, 3 storage and transport, 4 installation – Richter SAFERUN User Manual

Page 6: 1 general notes, 2 installation notes, Operation, Storage and transport, General notes, Installation notes, 4installation

background image

Series MNK, MNK-B,

SAFERUN

®

Pump condition monitoring system

Page 6

9230-070-en

Revision 01

TM 7691

Edition 11/2009

SAFERUN

®

transformer

Fig. 4

SAFERUN

®

can unit

Fig. 5

1

Jack for connection to the SAFERUN

®

trans-

former (terminals 1-5)

2

Sensor unit

3

Can

3.2.2 Operation

The status display and operation of the system can be
performed via:

coloured LEDs on site
handheld unit (PDA) with suitable radio interface
HART protocol
the service program via the built-in serial interface
(special cable required).

3.3 Storage and transport

Standard A: Pump is ordered with SAFERUN

®

.

Standard B: SAFERUN

®

transformer is retrofitted as

SAFERUN

®

can unit is standard.

The consignment is to be inspected for completeness
and any possible in-transit damage immediately after
the goods have been received.
If any damage is discovered, the unit must not be put
into operation.
Make sure during in-house transport that no damage
occurs.
If the unit is not installed immediately after delivery, it
must be properly stored (see "Installation and Operat-
ing Manual for the MNK and MNK-B").

4

Installation

4.1 General notes

The SAFERUN

®

is certified as intrinsically

safe electrical equipment in category 2 due to
EC type examination certificates of a "notified

body":

for installation in zone 1 and 2 of the potentially
explosive area
with intrinsically safe electric circuits in category 2
with protection level "ib" of the potentially explosive
area.

Non-hazardous operation is only guaranteed if the
operating manual and the relevant safety and EN
standards or VDE regulations are observed.

The SAFERUN

®

transformer may only be

connected to the original SAFERUN

®

can

from Richter.

4.2 Installation notes

As a standard feature, the SAFERUN

®

is attached

directly to the pump with a holding plate.

The SAFERUN

®

can unit is introduced into the

bracket like the standard can unit. The plug con-
nection of the SAFERUN

®

can unit is located on

the left as standard (as viewed from the direction
of the motor).
The holding plate with the SAFERUN

®

is attached

on the left on the bracket or on the bearing pedes-
tal as standard.
The protective cap of the SAFERUN

®

can unit is

unscrewed and instead the plug of the SAFERUN

®

is screwed onto the jack.

1

5

2

6

4

1

2

3

3

7