Model 2850, Water conditioner flow diagrams (cont’d.), Page 5 – Watts Fleck 2850 Brass Valve User Manual
Page 5
Printed in U.S.A.
Page 5
MODEL 2850
Water Conditioner Flow Diagrams (Cont’d.)
Hard water enters unit at valve inlet
flows up into injector housing and down through nozzle and
throat
around the piston down through mineral enters center tube through bottom
distributor
flows up through center tube around piston and out through drain line.
Hard water enters unit at valve inlet
flows directly from inlet down
through mineral into center tube bottom distributor and up through
center tube
around piston and out through the drain line.
Hard water enters unit at valve inlet
flows up through the injector
housing
through the brine valve to refill the brine tank.
4
6
5
SLOW RINSE POSITION
RAPID RINSE
BRINE TANK REFILL POSITION