G. TROUBLESHOOTING

RO TROUBLE SHOOTING GUIDE

SYMPTOMS

Salt Passage

Permeate Flow

Pressure Drop

Location

Possible Causes

Verification

Corrective Action

Normal to
increased

Decreased Normal

to

increased

Predominantly
first stage

Metal oxide

Analysis of metal
ions in cleaning
solution.

Improved pretreatment
to remove metals.
Cleaning with acid
cleaners.

Normal to
increased

Decreased Normal

to

increased

Predominantly
first stage

Colloidal fouling

SDI measurement
of feed/ X-ray
diffraction
analysis of
cleaning sol.
Residue.

Optimize pretreatment
system for colloidal
removal. Clean with
high pH, anionic
detergent formulation.

Increased

Decreased Increased Predominantly

last stage

Scaling
(CaSO

4

, CaSO

3

,

BaSO

4

, SiO

2

)

Analysis of metal
ions in cleaning
sol. Check LSI of
reject. Calculate
maximum
solubility for
CaSO

4

, BaSO

4

,

SiO

2

in reject

analysis.

Increase acid addition
and scale inhibitor for
CaSO

3

and CaSO

4

.

Reduce recovery.
Clean with an acid
formulation for
CaCO

3

, CaSO

4

and

BaSO

4

.

Normal to
moderate
increase

Decreased Normal

to

moderate
increase

Can occur in
any stage

Biological fouling

Bacteria count in
permeate and
reject. Slime in
pipes and vessels.

Shock dosage of
sodium bisulfite.
Continuous feed of
low conc. Of bisulfite
at reduced pH.
Formaldehyde
sterilization. Clean
with alkaline anionic
surfactant. Chlorine
dosage up-stream with
subs. Dechlorination.
Replace cartridge
filters.

Decreased or
moderately
increased

Decreased

Normal

All stages

Organic fouling

Destructive
testing, e.g. IR
reflection
analysis.

Optimization of
pretreatment system
(e.g. coagulation
process.)
Resin/activated carbon
treatment. Clean with
high pH detergent.

Increased

Increased

Decreased

Most severe in
the first stage

Chlorine oxidant
attack

Chlorine analysis
of feed.
Destructive
element test.

Check chlorine feed
equipment and
dechlorination
equipment.

Increased

Increased

Decreased

Most severe in
the first stage

Abrasion of
membrane by
crystalline material

Microscopic
solids analysis of
feed. Destructive
element test.

Improved
pretreatment. Check
all filters for media
leakage.

Increased Normal

to

increased

Decreased

At random

O-ring leaks, End
or side seal glue
leaks.

Probe test.
Vacuum test.
Colloidal
material passage.

Replace O-rings.
Repair or replace
elements.

Increased

Normal to low

Decreased

All stages

Conversion too
high.

Check flows and
pressures against
design guidelines

Reduce conversion
rate. Calibrate sensors.
Increase analysis and
data collection.