AIR DELIVERY — 559F180-300 UNITS (cont)

559F216 (18 TON)

Airflow

(Cfm)

Standard Belt-Drive Motor

External Static Pressure (in. wg)

0.2

0.4

0.6

0.8

1.0

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

5400

650

1.24

1095

750

1.54

1366

844

1.84

1646

930

2.14

1942

1011

2.54

2258

5500

658

1.30

1143

757

1.60

1418

850

1.90

1701

935

2.20

2000

1015

2.60

2318

6000

702

1.60

1428

796

1.90

1723

884

2.30

2025

965

2.60

2339

1041

3.00

2669

6500

747

2.00

1757

835

2.30

2073

919

2.70

2394

997

3.10

2725

1070

3.40

3069

7000

792

2.40

2138

877

2.80

2476

957

3.20

2816

1031

3.50

3165

1102

3.90

3525

7200

856

2.60

2311

893

3.00

2657

973

3.40

3006

1045

3.74

3362

1115

4.14

3729

7500

838

2.90

2571

918

3.30

2929

996

3.70

3290

1067

4.10

3658

1135

4.50

4035

8000

885

3.40

3060

962

3.90

3440

1036

4.30

3822

1105

4.70

4209

1170

5.20

4604

8500

932

4.00

3610

1005

4.50

4011

1077

4.90

4414

1143

5.40

4821

9000

980

4.70

4223

1050

5.20

4647

1119

5.70

5071

559F216 (18 TON) (cont)

Airflow

(Cfm)

Standard Belt-Drive Motor

External Static Pressure (in. wg)

1.2

1.4

1.6

1.8

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

5400

1079

2.68

2597

1165

3.32

2954

1238

3.72

3332

1308

4.14

3727

5500

1093

3.00

2658

1168

3.40

3017

1240

3.80

3396

1310

4.20

3793

6000

1115

3.40

3018

1186

3.80

3385

1251

4.20

3771

1322

4.70

4175

6500

1140

3.80

3429

1208

4.30

3805

1274

4.70

4198

1338

5.20

4609

7000

1169

4.40

3898

1233

4.80

4285

1296

5.20

4687

1358

5.70

5106

7200

1181

4.60

4108

1245

5.04

4500

7500

1199

4.90

4422

1262

5.40

4822

8000

1232

5.60

5008

8500

9000

LEGEND

Bhp

Brake Horsepower Input to Fan

FIOP

Factory-Installed Option

Watts — Input Watts to Motor

NOTES:
1. Boldface indicates field-supplied drive is required. (See Note 2.)
2. Factory-shipped motor drive range is 1047 to 1251 rpm. Other rpms

require a field-supplied drive.

3. Maximum continuous bhp is 5.90 and maximum continuous watts

are 5180. Do not adjust motor rpm such that motor maximum bhp
and/or watts is exceeded at the maximum operating cfm.

4. Static pressure losses (i.e., economizer) must be added to external

static pressure before entering Air Delivery table. See page 47 for
accessory/FIOP static pressure information.

5. Interpolation is permissible. Do not extrapolate.
6. Fan performance is based on wet coils, clean filters, and casing

losses.

7. Extensive motor and drive testing on these units ensures that the full

horsepower range of the motor can be utilized with confidence. Us-
ing your fan motors up to the watts or bhp rating shown will not result
in nuisance tripping or premature motor failure. Unit warranty will not
be affected.

8. Minimum allowable cfm is 300 cfm/ton.
9. Use of a field-supplied motor may affect wire sizing. Contact your lo-

cal representative for details. For additional information on motor
performance, refer to Evaporator-Fan Motor Performance table on
page 62.