beautypg.com

Model 4650, Water conditioner flow diagrams (cont’d.) 7 – Watts Fleck 4650 Hot Water Brass Valve User Manual

Page 13

background image

Printed in U.S.A.

Page 13

MODEL 4650

Water Conditioner Flow Diagrams (Cont’d.)

7

SETTLING RINSE POSITION

5 Minutes

8

BRINE TANK FILL POSITION

4 to 24 Minutes Adjustable Cycle

Hard water enters the unit at the valve inlet - flows
around the lower piston groove - thru the injector throat
- thru the brine valve and flow control to fill the brine
tank. Hard water also flows around the lower piston
groove - thru the passage to the top of tank - down thru
the resin and enters the distributor as conditioned
water. The conditioned water flows up thru the center
tube to the valve outlet.

Hard water enters the unit at the valve inlet - flows
around the lower piston groove - down thru the top
of tank passage - downward thru the resin - up the
distributor tube - thru the center hole in the piston
-over the top edge of the piston and out the drain
line.