Static Single-Point TEACH Procedure - Push Button

Static TEACH Procedure - Push Button

R55F Series Fiber-Optic Color Mark Sensors

page

5

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Push Button

Resulting Indicator Status

Press and hold STATIC button
until LO and DO indicators
alternately flash, then release
button.

LO and DO: Alternately flash green

: ON amber (indicating ready to

teach output ON condition)

Light Bar: Goes OFF

TEACH Condition #1
(Output ON state)

Present the output ON sensing
condition and single-click
STATIC button.

LO and DO: Alternately flash Green

: OFF (indicating ready to teach

output OFF condition)

Light Bar: Remains OFF

TEACH Condition #2
(Output OFF state)

Present the output OFF
sensing condition and single-
click STATIC button.

Contrast accepted: one of the ten
segments flashes for three seconds to
indicate relative contrast, and then the
sensor enters RUN mode.

Contrast too low: every other segment
flashes for three seconds to indicate low
contrast, and the sensor returns to TEACH
Condition #1.

SETUP

DO

LO

OFF

Delay

Switch Point

+

DYNAMIC

ST
A

T

IC

Press and Hold

2 seconds

SETUP

DO

LO

OFF

Delay

Switch Point

+

DYNAMIC

ST
A

T

IC

Single-click

SETUP

DO

LO

OFF

Delay

Switch Point

+

DYNAMIC

ST
A

T

IC

Single-click

Signal Strength
Light Bar

Push Button

Resulting Indicator Status

Press and hold STATIC button
until LO and DO indicators
alternately flash, then release
button.

SETUP

DO

LO

OFF

Delay

Switch Point

+

DYNAMIC

S

TAT

IC

Press and Hold

2 seconds

LO and DO: Alternately flash green

: ON amber (indicating ready to

teach output ON condition)

Light Bar: Goes OFF

TEACH Condition to be
Sensed (Output ON state)

Present the output ON sensing
condition and double-click
STATIC button.

SETUP

DO

LO

OFF

Delay

Switch Point

+

DYNAMIC

ST
A

T

IC

Double-click

LO or DO: depending on condition of

taught

: OFF

Light Bar: Two center segments are lit

if TEACH was successful.

NOTES:

1) The sensor will return to RUN mode if either TEACH condition is not registered within 90 seconds. Also,

TEACH mode may be cancelled by pressing and holding the push button for

2 seconds. In either case, the

sensor will revert to the previous conditions taught (i.e., exit without save).

2) If the sensing conditions are accepted at the end of TEACH Condition #2, the signal strength light bar flashes

one of its ten segments for three seconds to indicate relative sensing contrast. The higher the flashing
segment, the higher the measured sensing contrast. High contrast relates directly to sensing reliability. High-
contrast sensing applications are most tolerant of sensing variables, such as web flutter or variations in color
mark color or print density.

See page 8 for Remote