beautypg.com

Banner Q25 Series User Manual

Q25 sensors – ac-voltage series, Features, Models

background image

Printed in USA

01/05

P/N 121517

Q25 Sensors – ac-Voltage Series

Self-contained ac-operated sensors

Sensing Mode

Range

LED

Output

Model*

Opposed

20 m (66')

Infrared

950 nm

Q253E

LO

Q25AW3R

DO

Q25RW3R

Polarized

Retroreflective

2 m (79")

Visible Red

680 nm

LO

Q25AW3LP

DO

Q25RW3LP

Fixed-Field

25 mm (1") cutoff

Infrared

880 nm

LO

Q25AW3FF25

DO

Q25RW3FF25

50 mm (2") cutoff

LO

Q25AW3FF50

DO

Q25RW3FF50

100 mm (4") cutoff

LO

Q25AW3FF100

DO

Q25RW3FF100

* Standard 2 m (6.5') cable models are listed.

• 9 m (30') cable: add suffix “W/30” (e.g., Q253E W/30).

• 4-pin Micro-style QD models: add suffix “Q1” (e.g., Q253EQ1). A model with a QD connector requires a mating cable. (See page 7.)

P

Features

• Featuring EZ-BEAM

®

technology for reliable sensing without the need for

adjustments

• Rectangular 25 mm plastic housing with 18 mm threaded mounting base in

opposed, retroreflective or fixed-field modes

• Completely epoxy-encapsulated to provide superior durability, even in harsh

sensing environments to IP69K

• Innovative dual-indicator system takes the guesswork out of sensor performance

monitoring

• 20 to 250V ac (3-wire hookup); SPST solid-state switch output, maximum

load 300 mA

Models

WARNING . . .

Not To Be Used for Personnel Protection

Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.

These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety

applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition.

Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for

personnel protection.