Banner SMI30 Series—Intrinsically Safe User Manual
Page 7

The stainless steel aperture housing functions equally well with VALOX® and stainless steel sensor models. The glass lens is useful for
protecting the SM30's acrylic lens against substances that are hostile to acrylics, such as concentrated acids and alkalis and industrial
solvents.
Aperture sizes include the following:
• Round: .06", .12", and .70" diameter
• Slotted: .04", .10", and .20" wide
APG30S
Kit includes round apertures of 0.05 in, 0.12", and 0.70" diameter; slotted widths of 0.04",
0.10" and 0.20".
Used with SM30 and SMI30 models.
Intrinsic Safety Kits for use with Intrinsic Safe Sensors
Kit CI2BK-1 (36860) includes a CI3RC2 current amplifier, one RS- 11 socket, one DIN-rail mount, and one single-channel intrinsically
safe barrier.
Kit CI2BK-2 (36605) includes a CI3RC2 current amplifier, one RS- 11 socket, one DIN-rail mount, and one dual-channel intrinsically safe
barrier.
Barriers are available separately:
• Single channel barrier (model CIB-1, p/n 27030)
• Dual channel barrier (model CI2B-1, p/n 36865)
Mounting Brackets
SMB30C
• 30 mm split clamp, black
PBT bracket
• Stainless steel mounting
hardware included
• Mounting hole for 30 mm
sensor
66
56
13
A
B
Hole center spacing: A=ø 45
Hole size: B=ø 27.2
SMB30MM
• 12-ga. stainless steel
bracket with curved
mounting slots for versatile
orientation
• Clearance for M6 (¼ in)
hardware
• Mounting hole for 30 mm
sensor
70
57
A
B
C
57
Hole center spacing: A = 51, A to B = 25.4
Hole size: A = 42.6 x 7, B = ø 6.4, C = ø 30.1
SMB30S
• Swivel bracket with 30 mm
mounting hole for sensor
• Adjustable captive swivel
ball
• Black reinforced thermo-
plastic polyester
• Stainless steel mounting
and swivel locking hard-
ware included
Special Conditions for Safe Use. Parts of the enclosure are non-
conducting and may generate an ignition-capable level of ESD.
Clean the equipment with a damp cloth only.
SMI30 Series Intrinsically Safe Sensors
P/N 035331 Rev. E
www.bannerengineering.com - tel: 763-544-3164
7