Distance Settings
* Default settings
Switch 1
Switch 2
Switch 3
Distance
EU, CN Models
US, UK Models
0
0
0
2 m (6.6 ft)
3 m (9.8 ft)
0
0
1
3 m (9.8 ft)
4 m (13.1 ft)
0
1
0
4 m (13.1 ft)
5 m (16.4 ft)
0
1
1
6 m (19.7 ft)
6 m (19.7 ft)
1*
0*
0*
8 m (26.2 ft)
8 m (26.2 ft)
1
0
1
10 m (32.8 ft)
10 m (32.8 ft)
1
1
0
12 m (39.4 ft)
12 m (39.4 ft)
1
1
1
15 m (49.2 ft)
15 m (49.2 ft)
NOTE: Highest sensitivity is achieved only if sensing distance is 8 m (26.2 ft) or less
Sensitivity Selection
* Default settings
Switch 4
Switch 5
Switch 6
Sensitivity
0*
0*
0*
8 (Highest)
0
0
1
7
0
1
0
6
0
1
1
5
1
0
0
4
1
0
1
3
1
1
0
2
1
1
1
1 (Lowest)
NOTE: Use the sensitivity selection to ignore unwanted weak reflections within the field of view, and not to
narrow the beam width. Narrow-beam R-GAGE sensor models are available.
Output Configuration
* Default settings
Switch 7
Normally Open/Normally Closed
0*
N.O.
1
N.C.
R-GAGE™ QT50RAF Sensor
P/N 135460_web
Rev. E