ECONO-BEAM

®

Diffuse AC Sensors

Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN 55441 • Phone: 888.373.6767 • http://www.baneng.com • Email: [email protected]

WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or
replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period.
This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty
either expressed or implied.

ECONO-BEAM AC Diffuse Specifications

Certifications

Supply Voltage and Current

120V ac (±20%, 50-60 Hz)

Supply Protection Circuitry

Protected against transient voltages

Output Configuration

Solid-state (FET).
SE61AW1 models: normally open (light operate)
SE61RW1 models: normally closed (dark operate)

Output Rating

Maximum steady-state load capability 300 mA to 50°C ambient (122°F)
Inrush capability: 1 amp for 20 milliseconds (non repetitive)
Off-state leakage current: less than 50 µA rms
On-state voltage drop:

3 volts at 300 mA load,

2 volts at 15 mA load

Output Protection Circuitry

Protected against false pulse on power-up

Output Response Time

10 milliseconds ON and 10 milliseconds OFF
Response time specification of load should be considered when important.
(NOTE: 20 millisecond delay on power-up.)

Repeatability

2.3 milliseconds; independent of signal strength

Indicators

Red indicator LED on top of unit is ON whenever the sensor sees its modulated light source

Construction

Reinforced thermoplastic polyester housing, totally encapsulated and acrylic lenses

Environmental Rating

Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 12, and 13; IEC IP66

Connections

PVC-jacketed 3-wire 2 m (6.5') or 9 m (30') cables

Operating Conditions

Temperature:

0° to 50°C (32° to 122°F)

Maximum relative humidity: 90% at 50°C (non-condensing)

ECONO-BEAM AC Diffuse Hookup

bn

bk

bu

120V ac (

±

20%)

Load

Sensing Beam

Infrared, 880 nm

6.1 mm
(0.24")

LED Indicator

(Receiver Only)

140.4 mm

(0.56")

ECONO-BEAM AC Diffuse Dimensions