Remote line teach – Banner U-GAGE T30UX Ultrasonic Sensors User Manual
Page 6

Push Button
0.04 sec. < “click” < 0.8 sec.
Remote Line
0.04 sec. < T < 0.8 sec.
Procedure
Result
Procedure
Result
Power LED: ON
Teach Not Accepted
Output LED: Flashing
Power LED: OFF
Power LED: ON
Teach Not Accepted
Output LED: Flashing
Power LED: OFF
Output OFF
Output ON
Taught Position
(background surface)
Near
Range
Sensor
Output
ON
Sensor
Output
OFF
Any object in this area will switch
the output, whether or not the object
returns a good signal to the sensor.
Sensing Distance
Figure 5. An application for the Auto-Window feature (retroreflective mode)
Remote Line TEACH
General Notes
• Run Mode is the sensor’s normal operating condition
• The duration of each Pulse is defined as “T”: 0.04 < T < 0.8 s
T
• A Hold will exit TEACH MODE and return to Run Mode with previously saved changes. The duration of a Hold is: T > 2 s
• A Timeout will occur if a condition is not registered within 120 seconds, causing the sensor to return to Run Mode (during sensor
configuration only)
• Sensor configuration user feedback shown on Green LED. See flowchart.
• The Red Signal LED will be ON whenever the target is in view.
U-GAGE® T30UX Series with Discrete Output
6
www.bannerengineering.com - tel: 763-544-3164
P/N 138381_web
Rev. G