Banner U-GAGE T30UX Ultrasonic Sensors User Manual
Page 4

Output OFF
Output ON
Output OFF
Minimum
Limit
Maximum
Limit
Output ON
Output ON
Output OFF
Minimum
Limit
Maximum
Limit
Normally Closed Operation
Normally Open Operation
Figure 2. Teaching independent minimum and maximum limits
Push Button
0.04 sec. < “click” < 0.8 sec.
Remote Line
0.04 sec. < T < 0.8 sec.
Procedure
Result
Procedure
Result
TEACH
Mode
Push and hold the
Discrete push button
longer than 2 sec-
onds
Power LED: OFF
Output LED: ON
No action required; sensor is ready
for first limit teach
None
Teach First
Limit
Position the target for the first
limit (120 second time out)
Signal LED: Must be
ON Red or Flashing
Red
3
Position the target for the first limit
Signal LED: Must be
ON Red or Flashing
Red
3
“Click” the Discrete
push button
Teach Accepted
Power LED: OFF
Output LED: Flashing
Teach Not Accepted
Output LED: ON
Single-pulse the remote line
T
Teach Accepted
Power LED: OFF
Output LED: Flashing
Teach Not Accepted
Power LED: ON
Teach Sec-
ond Limit
Position the target for the sec-
ond limit (no time out)
Signal LED: Must be
ON Red or Flashing
Red
Position the target for the second
limit (no time out)
Signal LED: Must be
ON Red or Flashing
Red
“Click” the Discrete
push button
Teach Accepted
Output LED: ON or
OFF, depending on
NO or NC Mode
Power LED: ON
Teach Not Accepted
Output LED: Flashing
Power LED: OFF
Single-pulse the remote line
T
Teach Accepted
Output LED: ON or
OFF, depending on
NO or NC Mode
Power LED: ON
Teach Not Accepted
Output LED: Flashing
Power LED: OFF
3
Sensor will not Teach or indicate “Teach Not Accepted” when there is no signal present (Signal LED Red or Flashing Red)
U-GAGE® T30UX Series with Discrete Output
4
www.bannerengineering.com - tel: 763-544-3164
P/N 138381_web
Rev. G