3 removing the dosino from the dosing unit, Removing the dosino from the dosing unit, Figure 18 – Metrohm 800 Dosino User Manual
Page 33: Removing the 800 dosino from the 807 dosing unit

■■■■■■■■■■■■■■■■■■■■■■
5 Operation
800 Dosino
■■■■■■■■
25
6 Turn the dosing unit upside-down and press it together against a
tabletop.
The piston stopper should now be flush with the upper edge of the
housing of the dosing unit.
5.3
Removing the Dosino from the dosing unit
Caution
The Dosino can be removed from the dosing unit only if the Status LED
is permanently lit up or if the control device is switched off.
The valve disc of the dosing unit must be positioned at Port 2 (fill port,
exchange position)(see Figure 12, page 19) and the dosing piston must
be in zero position. Should this not be the case, then the active process
may need to be stopped and/or the dosing unit may need to be filled.
1
Figure 18
Removing the 800 Dosino from the 807 Dosing Unit
1
UNLOCK position
Remove the Dosino from the dosing unit as follows:
1 Fill the dosing unit.
The stopcock is then rotated automatically to the Exchange posi-
tion.
- 915 KF Ti-Touch (382 pages)
- 767 Calibrated Reference (23 pages)
- 940 Professional IC Vario ONE/SeS/Prep 2 (54 pages)
- 754 Dialysis Unit (49 pages)
- 815 Robotic Soliprep for LC (76 pages)
- Vision Manual (207 pages)
- tiamo 2.1 Manual (1532 pages)
- 825 Lab Link (37 pages)
- 808 Titrando (70 pages)
- 902 Titrando (52 pages)
- 756 KF Coulometer (163 pages)
- 756 KF Coulometer (162 pages)
- 940 Professional IC Vario ONE/LPG (98 pages)
- 850 Professional IC Anion MCS Prep 3 (154 pages)
- 850 Professional IC Anion MCS Prep 3 (152 pages)
- 904 Titrando (58 pages)
- 850 Professional IC Anion MSM-HC MCS Prep 2 (150 pages)
- 930 Compact IC Flex Oven/ChS/Deg (47 pages)
- 872 Extension Module Liquid handling (64 pages)
- 814 USB Sample Processor (90 pages)
- 814 USB Sample Processor (91 pages)
- 940 Professional IC Vario (43 pages)
- Vision – Tutorial (40 pages)
- 799 GPT Titrino (242 pages)
- 889 IC Sample Center (68 pages)
- 761 Compact IC (228 pages)
- 851 Titrando (100 pages)
- 748 DH Sample Changer (32 pages)
- 940 Professional IC Vario ONE/SeS/HPG (51 pages)
- 896 Professional Detector – Amperometry (62 pages)
- 877 Titrino plus (139 pages)
- 881 Compact IC pro – Anion (129 pages)
- 940 Professional IC Vario ONE/ChS/HPG (112 pages)
- 930 Compact IC Flex Deg (41 pages)
- 840 PC Control 5.0 / Touch Control (351 pages)
- 940 Professional IC Vario ONE/Prep 1 (45 pages)
- 776 Dosimat (42 pages)
- 717 Sample Changer (36 pages)
- 815 Robotic USB Sample Processor XL (113 pages)
- 815 Robotic USB Sample Processor XL (114 pages)
- 940 Professional IC Vario ONE/SeS/PP (126 pages)
- 838 Advanced Sample Processor Installation Instructions (109 pages)
- 700 Dosino (55 pages)
- 719 S Titrino (152 pages)