GLOW UP STRIP 100
230
(9.06")
170
(6.69")
115
(4.53")
130
(5.12")
1000
(39.37")
THE PROJECTOR WILL NOT SWITCH ON
TROUBLE
THE PROJECTOR WILL NOT SWITCH ON
DEFECTIVE PROJECTION
REDUCED LUMINOSITY
POSSIBLE CAUSES
CHECKS AND REMEDIES
No power supply.
LED burnt out or defective.
Signal transmission cable faulty or disconnected.
Incorrect addressing.
Fault in the electronic circuits.
Optic fault.
Dust or grease deposits.
Check the power supply voltage or battery charge.
Call an authorised technician.
Replace the cables.
Check addresses (see instructions).
Call an authorised technician.
Call an authorised technician.
Clean (see instructions).
CAUSE AND SOLUTION OF PROBLEMS
Source
10x LED RGBW Ostar (OSRAM)
Led pilot power
100W
Total output
Max 3400 lumens
Optics
Electronically controlled optic zoom
LED color temperature
6000K
Head adjustment
0 - 90°
Cooling
Natural Convection
Control
• Wireless DMX multimode: Master, Slave and
Repeater
• Antenna built in the case IP65
• Master: can transmit other slaves the synchroni-
sed DMX scenes saved on it, both as macros
and as DMX recorder.
• Repeater: Receives the signal from the master
and re-transmits it to other Slaves hidden from
the master
• XLR 5-pole DMX-in DMX-out standard sockets
• Default macros, user programmable macros.
• DMX recorder to save scene sequences.
User interface
• LCD display 2 lines with 16 characters each,
backlit LED, white on black
• 4 membrane buttons
External power
Full range 100-240V 50-60Hz, PowerCon connec-
tor, for both battery charge and normal operations
Input Power
• 200 VA GLOW UP STRIP 100
• 650 VA Flight Case
Body
• Body extruded in black anodized aluminium
• 2 carrying handles
• 4 non-slip rubber feet
Fittings
4 fast-look holes for omega hook-up
Safety
Eyebolts for safety cables
Weight
15 Kg
Protection rating
IP65
Valves
Compensation valve IP65
Battery
• Duration 5 hours full
• Carica da Flight Case o con PowerCon
• More than 2000 charge/deplete cycles
• No memory effect
• No acid leaks
Working position
Works in any position
CE Marking
Complies with the following European Directives
- 2006/95/EC (LVD)
- 2004/108/EC (EMC)
- 2011/65/EU (RoHS).
TECHNICAL DATA