Wiring diagram, Ct tb – Blakeslee DD-8 User Manual
Page 24

— 24 —
208 / 240 / 480 VAC
3 PHASE 60 HZ
SUPPLY LINES
HTR
MC
OL
EQUIPMENT
GROUND
CT
TB
G L
L 3
L 3
L 2
L1
T 3
L 2
T 2
T 1
HTR
MC
OL
L 3
L1
T 3
L 2
T 2
T 1
L 1
BOOSTER
CONTROL
CYCLE LIGHT
(AMBER)
TIMER MOTOR
WASH PUMP – TANK #1
WASH PUMP – TANK #2
RINSE-FILL
SOLENOID – TANK #2
POWER ON LIGHT
(RED)
A1
CR
1
A2
A1
A2
NC
P B–1
CR–1
MC-1-A
SW-3-2
MC-1
MC-2-A
MC
MC
MC
MC
TR
OL
OL
TR–1
TR–2
TR–2
COM
P B–1–1
TAS-2
S W-2
S W-2
S W–3–1 (TANK #2)
S W–4–1 (TANK #1)
DOOR SW
18
19
17
1
2
TAS-2
FUSE
TO LINE OR L1 SIDE OF
HEATER CONTACTOR
IN BOOSTER
THERMAL CYCLE
EXTENSION
NO
NC
NO
(3 PHASE)
(1 PHASE)
(3 PHASE)
(1 PHASE)
AUTO
FILL
SOL #2
TANK HEAT – TANK #1
RINSE-FILL
SOLENOID – TANK #1
SOL #1
TANK HEAT – TANK #2
7
7
7
7
3
8
5
2
2
2
2
SW-4-2
2
2
2
2
2
2
5
5
54
53
L3
53
54
T3
MC-2
L3
T3
14
14
12
13
5
6
6
6
6
4
4
12
13
13
14
7
P B-2
10
21
9
9
95
96
5
4
4
4
4
14
ON
FILL
ON
OFF
FILL
2
1 LT
2LT
L W C
TM
T A S
15
16
7
7
T A S
LWC
HC
S SOL
GC
HC
S SOL
GC
L1
FUSE
RINSE CONTROL
DISPENSER POWER & CONTROL CONNECTIONS
(PARTS & WIRING BY OTHERS)
DISPENSER
TRANSFORMER
K-1
K
NO
L2
5
2
6
2
H2
H1
440 - 480 VAC 3KV
ELECTRIC TANK HEATER
HTR
L2
L1
208 - 240 VAC SINGLE-PHASE
IMMERSION HEATER WIRING
208 - 240 VAC 3-PHASE
IMMERSION HEATER WIRING
H2
H1
HTR
HC
HC
L2
L1
L3
L1
L2
L1
#1
WASH TANK
HEATER
#2
WASH TANK
HEATER
#1
WASH TANK
HEATER
#2
WASH TANK
HEATER
1L1
1L2
HC1
HC2
H1
H2
H3
H4
1L1
1L2
1L3
HC1
HC2
H1
H2
H3
H4
L2
WIRING DIAGRAM