— 21 —

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

Poor rinse results

Rinse nozzles clogged

Clear rinse nozzles.

Line strainer clogged

Turn off water supply.

Clean line strainer screen.

Clogged solenoid valve

Contact your authorized service

provider.

Faulty solenoid

Contact your authorized service

provider.

Final rinse booster turned OFF

Turn booster ON.

Power supply to booster OFF

Restore power to booster.

Booster thermostat set too low

Increase temperature setting on

booster.

Water supply temperature too low

Water supply temperature must be

140° F min.

Water supply pressure to booster too

low. Must be 15-25 psi flow pressure.

Contact your authorized service

provider.

Water supply line too small.

Contact your authorized service

provider.

Water quality causing spotting.

Contact your detergent supplier for

remedies.

Wash tank not holding water

Drain not fully closed

Turn drain valve handle clockwise until

it stops.

Drain seat dirty

Turn off unit.

Drain tank.

Remove and clean standpipe drain plug

and seat.

Worn or damaged drain plug

Replace drain plug.

Wash tank will not drain

Clogged drain screen

Empty wash tank. Clean screen.

Drain line clogged or too small

Contact your authorized service

provider.

Mineral deposits on seat

Contact your authorized service

provider.