Main te nance 9, Trou ble shoot ing 9, Clean ing 9 – Bird Technologies 8141 User Manual
Page 19: Out side sur face 9, Maintenance, Troubleshooting, Cleaning, Outside surface
![background image](/manuals/583831/19/background.png)
Chapter 5
Maintenance
Troubleshooting
For corrections requiring repair or replacement of compo-
nents, refer to the appropriate section for your specific
model.
Cleaning
Outside Surface
The outside surface of the instrument, especially the cooling
fins, should be wiped free of dust and dirt when necessary.
Clean the RF input connector with a clean dry cloth. Use an
aerosol type non residue forming contact cleaner on the in-
accessible portions. Take special care to clean the metallic
contact surfaces and exposed face of the teflon insulator.
9
Problem
Possible Cause
Correction
Coolant oil leak
around clamping
band or radiator
Clamping bands not
tight
Tighten slightly with
screwdriver
Faulty O-ring (front)
Replace O-ring
Faulty diaphragm
Replace diaphragm
Overheating of
the radiator
Transmitter power
too high
Reduce transmitter
power
Coolant oil level too
low
Add more coolant oil
to the radiator
Accumulation of dirt
on cooling fins
Clean cooling fins
Faulty RF section
assembly, check
Rdc
Replace if needed
High or low dc
resistance values
Loose or faulty RF
connector
Tighten or replace as
needed
Faulty RF section
assembly
Replace if needed
Table 1
Troubleshooting