beautypg.com

Main te nance 9, Trou ble shoot ing 9, Clean ing 9 – Bird Technologies 8141 User Manual

Page 19: Out side sur face 9, Maintenance, Troubleshooting, Cleaning, Outside surface

background image

Chapter 5

Maintenance

Troubleshooting

For corrections requiring repair or replacement of compo-

nents, refer to the appropriate section for your specific

model.

Cleaning

Outside Surface

The outside surface of the instrument, especially the cooling

fins, should be wiped free of dust and dirt when necessary.

Clean the RF input connector with a clean dry cloth. Use an

aerosol type non residue forming contact cleaner on the in-

accessible portions. Take special care to clean the metallic

contact surfaces and exposed face of the teflon insulator.

9

Problem

Possible Cause

Correction

Coolant oil leak
around clamping
band or radiator

Clamping bands not
tight

Tighten slightly with
screwdriver

Faulty O-ring (front)

Replace O-ring

Faulty diaphragm

Replace diaphragm

Overheating of
the radiator

Transmitter power
too high

Reduce transmitter
power

Coolant oil level too
low

Add more coolant oil
to the radiator

Accumulation of dirt
on cooling fins

Clean cooling fins

Faulty RF section
assembly, check
Rdc

Replace if needed

High or low dc
resistance values

Loose or faulty RF
connector

Tighten or replace as
needed

Faulty RF section
assembly

Replace if needed

Table 1

Troubleshooting