Power and
Utility
Requirements
Other than the RF power input the Models 8141 and 8141-
010 has no need for an external source of power or utility
services.
Environmental
Requirements
The loads should be operated in as clean and vibration free
an environment as possible. The ambient temperature
range should remain within -40°C to +45°C (-40°F to
+113°F) for proper operation.
Items Supplied
The models are a self-contained unit, there are no addi-
tional parts other than this instruction book supplied. The
load is prefilled at the factory with the proper amount of
coolant.
Items Required
No additional items are required other than a coaxial cable
for connecting the RF source to the load. The load is fur-
nished with a Female N type connector. The cable should be
equipped with a Male N type plug. If the cable has any
other type of standard connector, then the load should be or-
dered with the appropriate type of mating connector.
Tools and Test
Equipment
Only a screwdriver is needed for disassembling for service.
An ohmmeter or resistance bridge with an accuracy of one
percent or better at 50 ohms, is useful for checking resistor
condition.
Specifications
Impedance
50 ohms nominal
VSWR
dc-1000 MHz
1000-18000 MHz
1800-2500 MHz
1.1:1 maximum
1.2:1 maximum
1.3:1 maximum
Connectors
Bird Quick Change “QC” Female N Normally
supplied.
Power Range
250 W continuous, 300 W intermittent (10
Minutes maximum).
Frequency Range
dc to 2500 MHz
Dimensions
9-9/16”L x 5-15/16”W x 8-1/2”H
(243 x 151 x 216 mm)
Ambient Temperature
40°C to +45°C (-40°F to +113°F)
Weight
10 lb (4.5 kg)
Operating Position
Horizontal only
Finish
Light grey powder coat
2